Zero-current chronopotentiometry for wired biosensors.
Article in Mikrochimica acta, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Enzyme biosensors used in continuous monitoring applications rely on amperometry as redout, which continuously draws energy, introduces ohmic drops and requires a reasonably reliable reference electrode. To help address these challenges a new experimental “zero-current” chronopotentiometry readout for wired glucose biosensors is introduced. The method records the transition time needed to chemically reduce the wired redox probe at the electrode by the enzymatically catalyzed turnover of glucose. After an electrochemical oxidation step, the open circuit potential changes over time because the enzymatic turnover continuously reduces the redox probe, thereby altering the ratio of reduced to oxidized form at the electrode. The exhaustion of the oxidized probe is indicated by an inflection of the potential at a specific transition time. The inverse value of the transition time is found to be proportional to glucose concentration, consistent with mass transport-limited kinetics across the diffusion limiting membrane and serves as sensor signal. For this reason, the specific potential value is not important for the measurement, allowing one to employ less accurate reference electrodes. Lower glucose concentrations result in longer transition times, resulting in a method that successfully covers the entire physiological concentration range.