Evidence map›Paper›PMID 41400686›Full record

ArticleRadiation and environmental biophysics2026

Efficacy and clinical use of novel high-resolution EPID-based 2D and 3D automated patient-specific quality assurance for SRS and SBRT patients.

Raghavendra Hajare, Taushiful Hoque, Shanmukhappa Kaginelli, Abhilasha Rao, Gopal Chandra Sahoo, Debasish Sahoo, Souvik Kapri, Suseenthar T G, Rohit Vadgaonkar, Raviteja Miriyala and 2 more

Abstract read
In one paragraph

Article in Radiation and environmental biophysics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Raghavendra HajareDepartment of Radiation Oncology, Homi Bhabha Cancer Hospital & Research Centre, Visakhapatnam, India. rhajare13@gmail.com.
Taushiful HoqueDepartment of Radiation Oncology, Homi Bhabha Cancer Hospital & Research Centre, Visakhapatnam, India.
Shanmukhappa KaginelliDivision of Medical Physics, JSS Academy of Higher Education and Research, Mysuru, India.
Abhilasha RaoDepartment of Radiation Oncology, Homi Bhabha Cancer Hospital & Research Centre, Visakhapatnam, India.
Gopal Chandra SahooDepartment of Radiation Oncology, Homi Bhabha Cancer Hospital & Research Centre, Visakhapatnam, India.
Debasish SahooDepartment of Radiation Oncology, Homi Bhabha Cancer Hospital & Research Centre, Visakhapatnam, India.
Souvik KapriDepartment of Radiation Oncology, Homi Bhabha Cancer Hospital & Research Centre, Visakhapatnam, India.
Suseenthar T GDepartment of Radiation Oncology, Homi Bhabha Cancer Hospital & Research Centre, Visakhapatnam, India.
Rohit VadgaonkarDepartment of Radiation Oncology, Homi Bhabha Cancer Hospital & Research Centre, Visakhapatnam, India.
Raviteja MiriyalaDepartment of Radiation Oncology, Homi Bhabha Cancer Hospital & Research Centre, Visakhapatnam, India.
Kiriti ChirikiDepartment of Radiation Oncology, Homi Bhabha Cancer Hospital & Research Centre, Visakhapatnam, India.
Umesh MahantshettyDepartment of Radiation Oncology, Homi Bhabha Cancer Hospital & Research Centre, Visakhapatnam, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) treatments should be delivered with caution because any delivery error can have a severe radiobiological impact on the patient due to the high dose per fraction used in such modalities. Therefore, a very high accuracy including a quality assurance program accompanying the entire treatment process is required. This study assessed the efficacy and clinical use of novel high-resolution 2-dimensional and 3-dimensional electronic portal imaging devices, an automated patient-specific quality assurance (PSQA) for SRS and SBRT patients. The dosimetric performance of these devices was evaluated by comparison with other detectors. Deliberate errors (errors of multi leave collimators (MLCs), gantry and collimator angle, and monitor unit (MU) changes) were introduced to assess the sensitivity of the devices. Twenty volumetric modulated arc therapy (VMAT) plans from various tumour sites, constrained to field sizes below 7.7 cm × 7.7 cm, were analyzed. Point dose measurements showed mean dose differences of 0.1% ± 1.5% for ionization chambers and 0.94% ± 1.8% for EPID compared to treatment planning system (TPS) calculations. With 2%/2 mm, average Gamma Passing Rates (GPRs) were 98.6% (film), 99.0% (SRS MapCHECK®), 98.7% (PDIP), 99.5% (PerFRACTION™,2D), 99.8% (PerFRACTION™,3D), and 93.2% for ArcCHECK®. At stringent 2%/1 mm criteria, high-resolution systems maintained > 94% pass rates while ArcCHECK® dropped to 73.5%. EPID showed comparable GPRs to films and SRS MapCHECK®. EPID detected most errors except small MLC shifts and gantry angle errors. It is concluded that EPID dosimetry can perform SRS and SBRT PSQA without additional devices. Thus, it offers a cost-effective, high-resolution alternative comparable to dedicated devices, enhancing clinical efficiency, without compromising accuracy.

Indexed as

Quality Assurance, Health CareRadiosurgeryAutomationHumansRadiometryRadiotherapy DosageRadiotherapy Planning, Computer-AssistedEPIDError detectionPSQASBRTSRTVMAT

Identifiers

PMID41400686
PMCPMC13135542

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked