Evidence map›Paper›PMID 41400083›Full record

ArticleJournal of orthopaedic research : official publication of the Orthopaedic Research Society2026

Load Transfer in Tibial Intramedullary Nailing: Effects of Fracture Level, Screw Configuration and Nail-Canal Clearance.

José L M Thiesen, Rafael Prado, Kodi E Kojima, Tóride S Celegatti, Paulo de Tarso R Mendonça, Carlos R M Roesler, Eduardo A Fancello

Abstract read
In one paragraph

Article in Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Load Transfer in Tibial Intramedullary Nailing: Effects of Fracture Level, Screw Configuration and Nail-Canal Clearance.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

José L M ThiesenGRANTE - Mechanical and Analysis Design Group, Department of Mechanical Engineering, Federal University of Santa Catarina (UFSC), Florianópolis, SC, Brazil.ORCID 0000-0002-1915-1824
Rafael PradoGRANTE - Mechanical and Analysis Design Group, Department of Mechanical Engineering, Federal University of Santa Catarina (UFSC), Florianópolis, SC, Brazil.ORCID 0009-0004-7811-0186
Kodi E KojimaIOT/HCFMUSP - Institute of Orthopedics and Traumatology, Hospital das Clínicas, School of Medicine, University of São Paulo (USP), São Paulo, SP, Brazil.ORCID 0000-0001-9543-081X
Tóride S CelegattiToride IND. COM. LTDA, Mogi Mirim, SP, Brazil.ORCID 0000-0001-6921-5673
Paulo de Tarso R MendonçaGRANTE - Mechanical and Analysis Design Group, Department of Mechanical Engineering, Federal University of Santa Catarina (UFSC), Florianópolis, SC, Brazil.ORCID 0000-0001-9469-4418
Carlos R M RoeslerLEBm - Biomechanical Engineering Laboratory, Department of Mechanical Engineering, Federal University of Santa Catarina (UFSC), Florianópolis, SC, Brazil.ORCID 0000-0002-9430-7059
Eduardo A FancelloGRANTE - Mechanical and Analysis Design Group, Department of Mechanical Engineering, Federal University of Santa Catarina (UFSC), Florianópolis, SC, Brazil.ORCID 0000-0001-9085-3901

Funding

The authors thank the following Brazilian funding agencies: CAPES (Coordination for the Improvement of Higher Education Personnel), Brazil, CNPq-(National Council for Scientific and Technological Development), Brazil and FAPESC-(Foundation for Research and Innovation of the State of Santa Catarina, Brazil; Grant No. 2021TR000634).
6 · The paper itself

Abstract

Intramedullary nails are widely recognized for their high stabilization capacity and are considered the gold standard for tibial fracture treatment. However, hardware failure, especially of distal screws, is frequently reported, especially in cases involving distal fractures. Although various experimental studies explore screw configurations, few quantify the mechanical loads acting on individual screws at different fracture locations. This study numerically evaluates two fixation systems: one with four screws and another with five, including an additional distal screw (DS3). The results show that the fifth screw significantly reduces von Mises stress, especially in distal fractures, though the improvements in overall stability are less pronounced. The mechanical implications on the inclusion of a clearance between the nail and endosteal surface are assessed. The stresses in the locking screws are significantly higher when the reaming clearance is included in the simulation. Despite mechanical advantages, clinical trade-offs such as increased surgical complexity and radiation exposure must be considered.

Indexed as

Bone NailsBone ScrewsFracture Fixation, IntramedullaryTibial FracturesBiomechanical PhenomenaHumansStress, MechanicalWeight-Bearingfracture fixationfracture healinginterlocking screwsIntramedullary nailtibial fractures

Identifiers

PMID41400083
PMCPMC12706723

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390