ArticleJournal of orthopaedic research : official publication of the Orthopaedic Research Society2026
Load Transfer in Tibial Intramedullary Nailing: Effects of Fracture Level, Screw Configuration and Nail-Canal Clearance.
Article in Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Load Transfer in Tibial Intramedullary Nailing: Effects of Fracture Level, Screw Configuration and Nail-Canal Clearance.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
Intramedullary nails are widely recognized for their high stabilization capacity and are considered the gold standard for tibial fracture treatment. However, hardware failure, especially of distal screws, is frequently reported, especially in cases involving distal fractures. Although various experimental studies explore screw configurations, few quantify the mechanical loads acting on individual screws at different fracture locations. This study numerically evaluates two fixation systems: one with four screws and another with five, including an additional distal screw (DS3). The results show that the fifth screw significantly reduces von Mises stress, especially in distal fractures, though the improvements in overall stability are less pronounced. The mechanical implications on the inclusion of a clearance between the nail and endosteal surface are assessed. The stresses in the locking screws are significantly higher when the reaming clearance is included in the simulation. Despite mechanical advantages, clinical trade-offs such as increased surgical complexity and radiation exposure must be considered.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.