First implementation of photon-counting dector computed tomography for optimizing segmentation in head-and-neck cancer radiotherapy.

Niccolò Bertini, Hubert S Gabryś, Hatem Alkadhi, Lotte Wilke, Patrick Wohlfahrt, Serena Psoroulas, Eugenia Vlaskou, Laura Motisi, Matthias Guckenberger, Stephanie Tanadini-Lang and 1 more

Abstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Niccolò BertiniDepartment of Radiation Oncology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091 Zurich, Switzerland.
Hubert S GabryśDepartment of Radiation Oncology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091 Zurich, Switzerland.
Hatem AlkadhiDiagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
Lotte WilkeDepartment of Radiation Oncology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091 Zurich, Switzerland.
Patrick WohlfahrtSiemens Healthineers, Varian, Cancer Therapy Imaging, Forchheim, Germany.
Serena PsoroulasDepartment of Radiation Oncology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091 Zurich, Switzerland.
Eugenia VlaskouDepartment of Radiation Oncology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091 Zurich, Switzerland.
Laura MotisiDepartment of Radiation Oncology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091 Zurich, Switzerland.
Matthias GuckenbergerDepartment of Radiation Oncology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091 Zurich, Switzerland.
Stephanie Tanadini-LangDepartment of Radiation Oncology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091 Zurich, Switzerland.
Panagiotis BalermpasDepartment of Radiation Oncology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091 Zurich, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and purpose: Photon-counting detector computed tomography (PCD-CT) offers advancements over conventional energy-integrating detector computed tomography (EID-CT). This study is the first to investigate the use of PCD-CT for delineation purposes. Materials and methods: Twelve patients with head-and-neck cancer were prospectively included. Delineation of clinical target volume (CTV) and organs at risk (OARs) was performed by three physicians using EID-CT (120 kVp) and PCD-CT at virtual monoenergetic levels of 140 keV and 50 keV. Segmentation accuracy was assessed and contouring-confidence was rated. Results: The ratio of the mean computed tomography dose index (CTDI) for EID-CT/PCD-CT for all patients was 2.72. The study revealed high inter-observer agreement for the mandible, oral cavity, parotid glands, and submandibular glands, with DSCs exceeding 0.8 across both EID-CT and PCD-CT. No differences in delineation agreement were observed, while a significant improvement was found for the lips (p = 0.001) and oral cavity (p = 0.003) when combining 140  keV and 50  keV images in PCD-CT compared to EID-CT. PCD-CT outperformed EID-CT in terms of contouring confidence. Conclusion: The study established the feasibility of PCD-CT for radiotherapy planning. PCD-CT-based delineation provides results comparable to EID-CT, with the added advantages of reduced radiation dose, improved image quality and higher delineation confidence. Significant improvements in delineating specific structures, such as the lips and oral cavity, were observed when combining multiple energy levels in PCD-CT.

Indexed as

computed tomography (CT)Head and neck cancerPhoton-countingRadiotherapy planningSegmentation

Identifiers

PMID41399699
PMCPMC12702377

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.