Evidence map›Paper›PMID 41398521›Full record

ArticleInternational journal of computer assisted radiology and surgery2026

Multimodal framework for swallow detection in video-fluoroscopic swallow studies using manometric pressure distributions from dysphagic patients.

Manuel Maria Loureiro da Rocha, Lisette van der Molen, Marise Neijman, Marteen J A van Alphen, Michiel M W M van den Brekel, Françoise J Siepel

Abstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Manuel Maria Loureiro da RochaRobotics and Mechatronics Group, University of Twente, Drienerlolaan 5, Enschede, 7522 NB, the Netherlands. m.m.rocha@utwente.nl.ORCID http://orcid.org/0009-0000-2108-6905
Lisette van der MolenHead and Neck Oncology, Netherlands Cancer Institute, Plesmanlaan 121, Amsterdam, 1066 CX, the Netherlands.ORCID http://orcid.org/0000-0002-0514-2142
Marise NeijmanHead and Neck Oncology, Netherlands Cancer Institute, Plesmanlaan 121, Amsterdam, 1066 CX, the Netherlands.ORCID http://orcid.org/0009-0006-1780-3055
Marteen J A van AlphenHead and Neck Oncology, Netherlands Cancer Institute, Plesmanlaan 121, Amsterdam, 1066 CX, the Netherlands.ORCID http://orcid.org/0000-0002-3551-6707
Michiel M W M van den BrekelHead and Neck Oncology, Netherlands Cancer Institute, Plesmanlaan 121, Amsterdam, 1066 CX, the Netherlands.ORCID http://orcid.org/0000-0002-6338-6743
Françoise J SiepelRobotics and Mechatronics Group, University of Twente, Drienerlolaan 5, Enschede, 7522 NB, the Netherlands.ORCID http://orcid.org/0000-0002-8165-0034

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeOropharyngeal dysphagia affects up to half of head and neck cancer (HNC) patients. Multi-swallow video-fluoroscopic swallow studies (VFSS) combined with high-resolution impedance manometry (HRIM) offer a comprehensive assessment of swallowing function. However, their use in HNC populations is limited by high clinical workload and complexity of data collection and analysis with existing software.

methodsTo address the data collection challenge, we propose a framework for automatic swallow detection in simultaneous VFSS-HRIM examinations. The framework identifies candidate swallow intervals in continuous VFSS videos using an optimized double-sweep optical flow algorithm. Each candidate interval is then classified using a pressure-based swallow template derived from three annotated samples, leveraging features such as normalized peak-to-peak amplitude, mean, and standard deviation from upper esophageal sphincter sensors.

resultsThe methodology was evaluated on 97 swallows from twelve post-head and neck cancer patients. The detection pipeline achieved 95% Recall and 92% F1-score. Importantly, the number of required HRIM annotations was reduced by 63%, substantially decreasing clinician workload while maintaining high accuracy.

conclusionThis framework overcomes limitations of current software for simultaneous VFSS-HRIM collection by enabling high-accuracy, low-input swallow detection in HNC patients. Validated on a heterogeneous patient cohort, it initiates the groundwork for scalable, objective, and multimodal swallowing assessment.

Indexed as

DeglutitionDeglutition DisordersHead and Neck NeoplasmsManometryVideo RecordingAlgorithmsFemaleFluoroscopyHumansMaleMiddle AgedPressureAutomatic swallow detectionHead and neck cancerImpedance manometryPressure templateVideo fluoroscopy

Identifiers

PMID41398521
PMCPMC13585989

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.