ArticleAnalytical chemistry2025
NMR Spectral Alignment Utilizing a CryoEM Motion Correction Algorithm.
Article in Analytical chemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
- Update of
Authors and funding
8 authors.
Funding
Abstract
With recent advances in magic-angle spinning (MAS) solid-state NMR (SSNMR) resolution, precise spectral alignment has become a critical bottleneck in data processing workflows. While solution NMR employs deuterium lock systems, most SSNMR probes still lack this capability; though a lock corrects for magnet drift and instabilities, it is not alone sufficient to account for field gradients, sample temperature differences, and pulse sequence effects that can contribute to referencing errors among several data sets. These offsets become particularly problematic in the lengthy multidimensional experiments that provide the foundation for resonance assignment and structure determination procedures. Currently, researchers rely on manual alignment through visual peak inspection─a qualitative approach that often overemphasizes prominent, outlying peaks while overlooking subtle, global patterns. This subjective process becomes increasingly impractical for use cases with lower sensitivity, such as large proteins with thousands of peaks. To address these challenges, here we present Automated NMR Spectral Alignment (
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.