ArticleApplied microscopy2025
From a clinical case to a general methodology to analyze prosthetic joint failure, by micro- and nano-characterization with SEM of intra-tissue wear debris.
Article in Applied microscopy, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Release of prosthesis debris at the tissue-implant interface is a major cause of aseptic loosening, a phenomenon that requires premature replacement of the prosthesis. The main objective of this paper is to propose a step-structured modus operandi for a reliable scanning electron microscopy (SEM) analysis of debris released from prostheses into the surrounding tissues. Following a proven methodology for the analysis of this wear debris would allow research and hospital laboratories to reduce time and obtain results associated with a common protocol and consequently, more comparable results. For developing the methodology, we chose the clinical case of a hip prosthetic revision, in which a Cr-Co head misalignment caused the wearing out of the polyethylene acetabular insert and a partial wear of the Ti-6Al-4 V acetabular cup. Samples of periprosthetic tissues, after being partially digested in a KOH basic solution, were investigated in vivo and in situ with SEM observations and Energy Dispersive X-rays Spectroscopy (EDXS) analyses. Although developed from a specific case study, this methodology is compatible and applicable to other standard cases as well. Regarding the set of samples we selected, a complete set of micro- and nano-structural analysis, compositional spectra and high-resolution images have been acquired, showing the morphology of the debris involved, and the agglomeration phenomena occurring in the tissue. The proposed protocol complements previous studies on tribological phenomena, underlying debris production at the tissue-prosthesis interface, best digestion techniques for fragment isolation, and nanotoxicology.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.