Validation of the count-reduction method for planar bone scintigraphy: a phantom study focused on hot-lesion detection.
Article in Radiological physics and technology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Poisson resampling can be used to synthesize low-count nuclear medicine images from full-count data. However, its fidelity relative to real short acquisitions remains uncertain. Using planar acquisitions of JSP and SIM2 bone phantoms filled with 99mTc, we compared the Poisson-generated and measured images at matched-count reductions (10–90%). The simulated total counts matched the measured counts at all reduction levels. The NMSE increased with a greater count reduction, and the values were similar between the groups at each level. In the bone phantom, the contrast ratio and CNR declined with fewer counts, whereas the %CV increased; the trends and values were similar between the simulated and measured images, even at a 90% reduction rate. These findings indicate that the Poisson-based count reduction can reproduce, without apparent systematic bias, the statistics and image-quality characteristics of true low-count images, supporting the safe and efficient optimization of low-dose and short-time protocols without additional patient scans.