Evidence map›Paper›PMID 41396206›Full record

ReviewEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2026

Beyond the two-year trial: real-World failure mechanisms of the simplify cervical disc.

Matthew Scott-Young, Scott Blumenthal, Todd Lanman, Donna Ohnmeiss, David Nielsen, Sukhman Riar, Cyrus Jensen

Abstract readReview
PubMed Publisher
In one paragraph

Review in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Matthew Scott-YoungGold Coast Spine, Southport, Australia. MScott-Young@goldcoastspine.com.au.
Scott BlumenthalCenter for Disc Replacement, Texas Back Institute, Plano, United States.
Todd LanmanCedars-Sinai Medical Center, Los Angeles, United States.
Donna OhnmeissCenter for Disc Replacement, Texas Back Institute, Plano, United States.
David NielsenGold Coast Spine, Southport, Australia.
Sukhman RiarGold Coast Spine, Southport, Australia. sriar@goldcoastspine.com.au.
Cyrus JensenNorthumbria Back Clinic, Newcastle Upon Tyne, United Kingdom.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCervical total disc replacement (TDR) is intended to preserve motion and reduce adjacent segment degeneration compared to anterior cervical discectomy and fusion (ACDF). The Simplify Cervical Disc (Globus Medical, Audubon, Pennsylvania), a polyetheretherketone (PEEK)-on-ceramic device with titanium-coated endplates, was approved following encouraging short-term outcomes. However, emerging registries and the Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) reports suggest an increase in device failures and revision surgeries, raising concerns about the device's long-term durability and biological compatibility.

methodsWe reviewed publicly available FDA MAUDE adverse event reports related to the Simplify disc replacement and the published literature on PEEK-on-ceramic wear mechanisms and titanium coating delamination. Representative clinical cases revised to ACDF procedures were also examined. Device bench testing data from the FDA summary were compared with real-world failure modes. Reported complications were categorized into wear, subsidence, migration, osteolysis, and revision outcomes.

resultsAnalysis of 96 MAUDE reports revealed diverse complications: osteolysis, device migration, persistent or worsening pain, and intraoperative retrieval difficulties. Histological evaluation of revision specimens demonstrated benign bone and fibrocartilage with foreign material, consistent with PEEK, titanium, and zirconia wear debris, an associated inflammatory reaction, and osteolysis. In vitro data confirm that PEEK-on-ceramic couples generate volumetric wear rates of 0.7-2.1 mm³/Mc, with titanium coating delamination further contributing to particulate load. Bench testing demonstrated mechanical adequacy under idealized conditions. However, retrieval findings highlight wear, coating failure, and osteolysis as potential failure pathways in real-world applications. Clinical outcomes after ACDF revision were favorable, suggesting effective salvage treatment.

conclusionsDespite promising early trial results, the Simplify disc demonstrates concerning failure mechanisms, including PEEK wear, titanium coating delamination, and subsequent osteolysis. The discrepancy between bench testing and retrieval analysis underscores the limitations of preclinical simulation in predicting in vivo wear. Vigilant post-market surveillance, independent registry reporting, and further long-term outcome studies are essential. Until durability is confirmed, cautious patient selection and readiness for revision remain critical in clinical practice.

Indexed as

Cervical VertebraeProsthesis FailureTotal Disc ReplacementBenzophenonesHumansIntervertebral Disc DegenerationKetonesPolyethylene GlycolsPolymersReoperationSpinal FusionTitaniumBenzophenonesKetonespolyetheretherketonePolyethylene GlycolsPolymersTitaniumCervical total disc arthroplastyCervical total disc replacementOsteolysisPEEK wear debrisRevision surgerySimplify cervical artificial disc

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.