Evidence map›Paper›PMID 41394486›Full record

ArticleBiomedical optics express2025

Simultaneous OCT A-scan depth ranging and C-scan volume imaging for intraoperative robotic retinal surgery guidance.

Yingxiong Xie, Yong Huang, Gui-Bin Bian, Boyu Yang, Yujie Bai, Yu-Peng Zhai, Yawen Deng, Pan Fu, Qun Hao

Abstract read
In one paragraph

Article in Biomedical optics express, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Yingxiong XieSchool of Optics and Photonics, Beijing Institute of Technology, No. 5 South Zhongguancun Street, Haidian, Beijing 100081, China.
Yong HuangSchool of Optics and Photonics, Beijing Institute of Technology, No. 5 South Zhongguancun Street, Haidian, Beijing 100081, China.ORCID https://orcid.org/0000-0002-7031-9709
Gui-Bin BianInstitute of Automation, Chinese Academy of Sciences, Beijing 100190, China.
Boyu YangSchool of Optics and Photonics, Beijing Institute of Technology, No. 5 South Zhongguancun Street, Haidian, Beijing 100081, China.
Yujie BaiSchool of Optics and Photonics, Beijing Institute of Technology, No. 5 South Zhongguancun Street, Haidian, Beijing 100081, China.
Yu-Peng ZhaiCollege of Integrated Circuits, Taiyuan University of Technology, Taiyuan, China.
Yawen DengInstitute of Automation, Chinese Academy of Sciences, Beijing 100190, China.
Pan FuInstitute of Automation, Chinese Academy of Sciences, Beijing 100190, China.
Qun HaoSchool of Optics and Photonics, Beijing Institute of Technology, No. 5 South Zhongguancun Street, Haidian, Beijing 100081, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Current subretinal injection systems combine surgical microscopy, optical coherence tomography (OCT), and robotic assistance to enable precise, depth-resolved, and tremor-free drug delivery to targeted retinal sites. Nevertheless, subretinal and intraretinal vascular injections remain constrained by two major challenges: (1) the inherent difficulty in simultaneously achieving wide-field, real-time imaging of fundus lesions at high spatial resolution, and (2) the requirement for precise intraocular localization of the needle tip quickly. Current fundus injection imaging methods provide limited accuracy in needle tip localization and require prolonged procedure time. To address this issue, we present a novel intraoperative OCT (iOCT) imaging system that integrates a single light source and dual-channel OCT detection to simultaneously acquire A-scan and C-scan data without incurring substantial additional cost. Using the A-scan component of the synchronization signal, high-speed and real-time distance detection of the retinal surface is performed in M-scan mode. Meanwhile, the C-scan component of the synchronization signal provides high spatial resolution imaging of retinal depth information. Combined with the ultra-wide field of view afforded by microscopic imaging, this approach facilitates rapid and extensive guidance for lesion localization in the fundus, while also allowing real-time intraoperative assessment of drug injection procedures. This system is integrated into a high-precision robot-assisted platform, enabling subretinal injections and retinal vascular injections within the ocular fundus. To the best of our knowledge, this is the first time that the simultaneous acquisition of A-scan and C-scan data has been proposed for subretinal injection and retinal vascular injection procedures. The A-scan sensitivity roll-off was characterized and exhibited a decrease of approximately 3 dB over a 0.88 mm depth range in water. The B-scan imaging with 1024 × 1024 pixels achieve a 97.7 fps with maximal lateral field of view (FOV) 16 mm. The system achieved an axial measurement accuracy of 15 µm for needle tip localization. The success rate of single attempt subretinal (6 out of 6 attempts) and optic disc vessel injections was 100% in both live (3 out of 3 attempts) and

Identifiers

PMID41394486
PMCPMC12698072

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.