Evidence map›Paper›PMID 41387510›Full record

ArticleScientific reports2025

Evaluating force and motion in posterior vitreous detachment manoeuvres using a robotic data acquisition system in cadaveric human eyes.

Reza Heidari, Esmaeil Asadi Khameneh, Ali Rastaghi, Mohammad Reza Dindarloo, Mohammad Mahdi Nazeri Ardakani, Mohammad Javad Ahmadi, Maryam Mohammadzadeh, Hamid Riazi-Esfahani, Alireza Lashay, Mohammad Motaharifar and 3 more

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Reza HeidariApplied Robotics and AI Solutions (ARAS), Faculty of Electrical Engineering, K. N. Toosi University of Technology, Seyed-Khandan Brg., Shariati Ave., 16317-14191, Tehran, Iran.
Esmaeil Asadi KhamenehTranslational Ophthalmology Research Centre, Farabi Eye Hospital, Tehran University of Medical Sciences, 13366-16351, Tehran, Iran.
Ali RastaghiApplied Robotics and AI Solutions (ARAS), Faculty of Electrical Engineering, K. N. Toosi University of Technology, Seyed-Khandan Brg., Shariati Ave., 16317-14191, Tehran, Iran.
Mohammad Reza DindarlooApplied Robotics and AI Solutions (ARAS), Faculty of Electrical Engineering, K. N. Toosi University of Technology, Seyed-Khandan Brg., Shariati Ave., 16317-14191, Tehran, Iran.
Mohammad Mahdi Nazeri ArdakaniApplied Robotics and AI Solutions (ARAS), Faculty of Electrical Engineering, K. N. Toosi University of Technology, Seyed-Khandan Brg., Shariati Ave., 16317-14191, Tehran, Iran.
Mohammad Javad AhmadiApplied Robotics and AI Solutions (ARAS), Faculty of Electrical Engineering, K. N. Toosi University of Technology, Seyed-Khandan Brg., Shariati Ave., 16317-14191, Tehran, Iran.
Maryam MohammadzadehTranslational Ophthalmology Research Centre, Farabi Eye Hospital, Tehran University of Medical Sciences, 13366-16351, Tehran, Iran.
Hamid Riazi-EsfahaniTranslational Ophthalmology Research Centre, Farabi Eye Hospital, Tehran University of Medical Sciences, 13366-16351, Tehran, Iran.
Alireza LashayTranslational Ophthalmology Research Centre, Farabi Eye Hospital, Tehran University of Medical Sciences, 13366-16351, Tehran, Iran.
Mohammad MotaharifarDepartment of Electrical Engineering, University of Isfahan, Sanaat Bldg., 81746-73441, Isfahan, Iran.
Seyed-Farzad MohammadiTranslational Ophthalmology Research Centre, Farabi Eye Hospital, Tehran University of Medical Sciences, 13366-16351, Tehran, Iran. sfmohammadi@sina.tums.ac.ir.
Mahdi TavakoliDepartment of Electrical and Computer Engineering and Department of Biomedical Engineering, University of Alberta, T6G 1H9, Edmonton, AB, Canada.
Hamid D TaghiradApplied Robotics and AI Solutions (ARAS), Faculty of Electrical Engineering, K. N. Toosi University of Technology, Seyed-Khandan Brg., Shariati Ave., 16317-14191, Tehran, Iran. taghirad@kntu.ac.ir.

Funding

Iran National Science Foundation 4024081
6 · The paper itself

Abstract

Deep vitrectomy, a complex ophthalmic procedure, demands precise instrument control and remains challenging to master. This study evaluated the ARASH:ASiST robotic system as a platform for real-time, quantitative assessment of deep vitrectomy in a pre-clinical setting using cadaveric human eyes. The system records force and motion data without disrupting the surgical workflow. Cadaveric eyes were prepared under strict safety protocols, and a mannequin head with a customised eye holder was designed, refined through repeated testing, and approved by surgeons to fully imitate real-world conditions. Four surgeons with different levels of experience, defined by their years of practice, performed the “drunk walk” manoeuvre while intraoperative force, positional, and temporal data were captured. Despite the inherent limitations of human cadaveric eyes, the aim was to reproduce the drunk walk method as a precise, predefined trajectory for posterior vitreous detachment induction. In total, 14 surgical trials were recorded: 2 from one expert surgeon (right-handed), 4 from two fellows (right-handed), and 8 from one intermediate surgeon, who performed four procedures with each hand. Quantitative metrics, including Normalised Jerk, Force Range, Peak Force Magnitude, and Force RMS, were used to compare individual performances. Group-level comparisons between expert, fellow, and intermediate surgeons were conducted using ANOVA and Kruskal–Wallis tests. While not statistically significant, likely due to the limited sample size, the analysis of descriptive statistics and effect sizes indicated potential trends in performance metrics across experience levels, highlighting the feasibility of the platform for capturing such variations. During data acquisition, the robotic system’s remote-centre-of-motion was accurately calibrated with laser-based technology, while encoders and force sensors were also precisely calibrated. The system’s real-time graphical interface provided immediate feedback and enabled detailed postoperative analysis. Usability testing confirmed its practicality and non-intrusiveness. Overall, the ARASH:ASiST system demonstrates feasibility as an objective platform for the evaluation of deep vitrectomy based on ex vivo results. These findings support further validation of this prototype in synthetic and clinical environments.

Indexed as

RoboticsRobotic Surgical ProceduresVitrectomyVitreous DetachmentCadaverHumansMotionCadaveric Human EyesSurgical Data AcquisitionVitreoretinal Surgery

Identifiers

PMID41387510
PMCPMC12783799

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.