Evidence map›Paper›PMID 41387461›Full record

ArticleNature communications2025

Wireless battery-free ultrathin lithium-niobate resonator as wearable and implantable electronics for continuous monitoring of mechanical vital signs.

Lianjie Zhou, Pengchuan Liu, Junhan Liu, Wenlou Yuan, Zhongyuan Wu, Dian Xu, Bofan Hu, Yuting Shao, Yifei Lu, Ningge Huang and 12 more

Abstract read
In one paragraph

Article in Nature communications, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

22 authors.

Lianjie Zhou *Institute of Optoelectronics & College of Future Information Technology, Shanghai Frontiers Science Research Base of Intelligent Optoelectronics and Perception, Department of Materials Science, Fudan University, Shanghai, China.ORCID http://orcid.org/0000-0002-9285-2176
Pengchuan Liu *Institute of Optoelectronics & College of Future Information Technology, Shanghai Frontiers Science Research Base of Intelligent Optoelectronics and Perception, Department of Materials Science, Fudan University, Shanghai, China.
Junhan LiuInstitute of Optoelectronics & College of Future Information Technology, Shanghai Frontiers Science Research Base of Intelligent Optoelectronics and Perception, Department of Materials Science, Fudan University, Shanghai, China.
Wenlou YuanState Key Laboratory of Materials for Integrated Circuits, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China.
Zhongyuan WuInstitute of Optoelectronics & College of Future Information Technology, Shanghai Frontiers Science Research Base of Intelligent Optoelectronics and Perception, Department of Materials Science, Fudan University, Shanghai, China.
Dian XuSchool of Mechanics and Aerospace Engineering, State Key Laboratory of Structural Analysis, Optimization and CAE Software for Industrial Equipment, and International Research Center for Computational Mechanics, Dalian University of Technology, Dalian, China.
Bofan HuInstitute of Optoelectronics & College of Future Information Technology, Shanghai Frontiers Science Research Base of Intelligent Optoelectronics and Perception, Department of Materials Science, Fudan University, Shanghai, China.
Yuting ShaoDepartment of Ophthalmology, Tongji Eye Institute, Tongji Hospital, School of Medicine, Tongji University, Shanghai, China.
Yifei LuInstitute of Optoelectronics & College of Future Information Technology, Shanghai Frontiers Science Research Base of Intelligent Optoelectronics and Perception, Department of Materials Science, Fudan University, Shanghai, China.
Ningge HuangInstitute of Optoelectronics & College of Future Information Technology, Shanghai Frontiers Science Research Base of Intelligent Optoelectronics and Perception, Department of Materials Science, Fudan University, Shanghai, China.
Jiahao LiInstitute of Optoelectronics & College of Future Information Technology, Shanghai Frontiers Science Research Base of Intelligent Optoelectronics and Perception, Department of Materials Science, Fudan University, Shanghai, China.ORCID http://orcid.org/0009-0003-6574-7455
Zhongzheng LiInstitute of Optoelectronics & College of Future Information Technology, Shanghai Frontiers Science Research Base of Intelligent Optoelectronics and Perception, Department of Materials Science, Fudan University, Shanghai, China.
Fuying LiangInstitute of Optoelectronics & College of Future Information Technology, Shanghai Frontiers Science Research Base of Intelligent Optoelectronics and Perception, Department of Materials Science, Fudan University, Shanghai, China.
Xiaojun WuInstitute of Optoelectronics & College of Future Information Technology, Shanghai Frontiers Science Research Base of Intelligent Optoelectronics and Perception, Department of Materials Science, Fudan University, Shanghai, China.
Lichao MaInstitute of Optoelectronics & College of Future Information Technology, Shanghai Frontiers Science Research Base of Intelligent Optoelectronics and Perception, Department of Materials Science, Fudan University, Shanghai, China.
Ming WangState Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, China.ORCID http://orcid.org/0000-0003-0976-9871
Zengfeng DiState Key Laboratory of Materials for Integrated Circuits, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China.ORCID http://orcid.org/0000-0002-9357-5107
Rui LiSchool of Mechanics and Aerospace Engineering, State Key Laboratory of Structural Analysis, Optimization and CAE Software for Industrial Equipment, and International Research Center for Computational Mechanics, Dalian University of Technology, Dalian, China.ORCID http://orcid.org/0000-0001-6051-4204
Yanlong BiDepartment of Ophthalmology, Tongji Eye Institute, Tongji Hospital, School of Medicine, Tongji University, Shanghai, China.
Fan XuInstitute of Mechanics and Computational Engineering, Department of Aeronautics and Astronautics, College of Intelligent Robotics and Advanced Manufacturing, State Key Laboratory of Coatings for Advanced Equipment, Fudan University, Shanghai, China.ORCID http://orcid.org/0000-0003-3910-5398
Yongfeng MeiInstitute of Optoelectronics & College of Future Information Technology, Shanghai Frontiers Science Research Base of Intelligent Optoelectronics and Perception, Department of Materials Science, Fudan University, Shanghai, China.
Enming SongInstitute of Optoelectronics & College of Future Information Technology, Shanghai Frontiers Science Research Base of Intelligent Optoelectronics and Perception, Department of Materials Science, Fudan University, Shanghai, China. sem@fudan.edu.cn.ORCID http://orcid.org/0000-0002-2658-904X

Funding

National Natural Science Foundation of China (National Science Foundation of China) 62204057
6 · The paper itself

Abstract

Continuous monitoring of physiological parameters associated with dynamic biomechanics, such as intracranial pressure (ICP) and vital signs, is important for clinical diagnosis of brain diseases and timely medical intervention. Current skin-interfaced and implant technologies face challenges in terms of bulky tethers and/or percutaneous wires with high infection risks. Here, we report the wireless, battery-free, and lightweight devices for both wearable and fully implantable applications. The devices incorporate an ultrathin piezoelectric resonator with suspended lithium niobate thin film (LNTF, 3 μm thick), enabling the wireless tracking of mechanophysiological signals by detecting variations in resonance frequency. We experimentally and computationally establish the operational principles of the resonator sensor and assess the device performance as wearables for dynamically monitoring artery pulse and apnea events during respiration. Implantable wireless pressure sensors adapted from this scheme allow for untethered, minimally invasive ICP sensing with a low detection limit of 0.15 mmHg over a wide range up to 240 mmHg. In vivo experiments performed on rat models validate the device capabilities of accurately capturing clinically relevant ICP variations and elevated levels of ICP under pathophysiological conditions of hydrocephalus, with excellent biocompatibility after long-term implantation periods. These findings create the clinical significance of such battery-less and wireless devices for precise characterization of dynamic biomechanics of living tissues.

Indexed as

NiobiumVital SignsWearable Electronic DevicesWireless TechnologyAnimalsElectric Power SuppliesEquipment DesignHumansHydrocephalusIntracranial PressureMaleMonitoring, PhysiologicOxidesProstheses and ImplantsRatsRats, Sprague-Dawleylithium niobateNiobiumOxides

Identifiers

PMID41387461
PMCPMC12816610

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390