Evidence map›Paper›PMID 41385205›Full record

ArticleIndian journal of ophthalmology2026

Diagnostic accuracy of Bruch's membrane opening minimum rim width for detecting glaucoma in Indian myopic eyes.

Mohideen Abdul Kader, Jeyapriya Thangavel, Madhavi Ramanatha Pillai, Shivam Gupta, Mohammed Sithiq Uduman, Rengappa Ramakrishnan

Abstract read
In one paragraph

Article in Indian journal of ophthalmology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mohideen Abdul KaderDepartment of Glaucoma, Aravind Eye Hospital and PG Institute of Ophthalmology, Tirunelveli, Tamil Nadu, India.
Jeyapriya ThangavelDepartment of Glaucoma, Aravind Eye Hospital and PG Institute of Ophthalmology, Tirunelveli, Tamil Nadu, India.
Madhavi Ramanatha PillaiDepartment of Glaucoma, Aravind Eye Hospital and PG Institute of Ophthalmology, Tirunelveli, Tamil Nadu, India.
Shivam GuptaDepartment of Glaucoma, Aravind Eye Hospital and PG Institute of Ophthalmology, Tirunelveli, Tamil Nadu, India.
Mohammed Sithiq UdumanDepartment of Biostatistics, Aravind Eye Hospital and PG Institute of Ophthalmology, Tirunelveli, Tamil Nadu, India.
Rengappa RamakrishnanDepartment of Glaucoma, Aravind Eye Hospital and PG Institute of Ophthalmology, Tirunelveli, Tamil Nadu, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo analyze Bruch's membrane opening minimum rim width (BMO-MRW) for detecting glaucoma in patients with myopia < -6D and assessment of peripapillary retinal nerve fiber layer thickness (pRNFLT).

methodsOne eye was randomly selected from each of the 90 subjects (A-30 normal controls, B-30 with glaucoma suspect, and C-30 with primary open-angle glaucoma [POAG]). All patients underwent baseline ophthalmic evaluation. BMO- MRW and pRNFLT data were obtained using spectral-domain optical coherence tomography (Spectralis, Heidelberg Engineering GmbH, Heidelberg, Germany). The area under the receiver operating characteristic curves (AUC) for global and sectoral thickness parameters was calculated.

resultsSectoral analysis of BMO-MRW for the discrimination of early glaucoma in all myopic subjects showed significantly better diagnostic performance than pRNFLT in temporal (0.85 (0.77 to 0.94) P = 0.014), temporal superior (TS) (0.90 (0.83 to 0.98) P = 0.005), and nasal inferior quadrants (0.92 (0.86 to 0.97) P = 0.022) with 95% CI. When discriminating early glaucoma from the suspect, overall the diagnostic performance of BMO-MRW was higher than that of pRNFLT, with significant differences in the temperosuperior quadrant (0.85 (0.74 to 0.95) 95% CI, P = 0.047).

conclusionBMO-MRW had better diagnostic performance than RNFL thickness and is a useful parameter for detecting glaucoma in myopic eyes (≤-6D) with POAG.

Indexed as

Bruch MembraneGlaucoma, Open-AngleIntraocular PressureMyopiaOptic DiskRetinal Ganglion CellsTomography, Optical CoherenceVisual FieldsAdultFemaleHumansIndiaMaleMiddle AgedNerve FibersReproducibility of ResultsBruch’s membrane openingglaucomaminimum rim widthmyopiaOCT

Identifiers

PMID41385205
PMCPMC13002007

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.