Evaluation of carbonyl collection methods in electronic cigarette aerosols.
Article in Frontiers in chemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Flavoring Compound Chemical Class and Vaping Conditions Determine Toxic Carbonyl Emissions from E-Cigarettes.Chemical research in toxicology · 2026Article
- Evaluation of carbonyl collection methods in electronic cigarette aerosols.Frontiers in chemistry · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
Introduction: This study evaluated the performance of three carbonyl collection media that are frequently used in electronic cigarette (e-cig) studies, namely: 2,4-Dinitrophenyl hydrazine (DNPH) silica impregnated cartridges (C), a DNPH-coated glass fiber filter (DF), and an impinger with a DNPH solution (I). Methods: These collection methods were tested with a 'mod' and a 'pod' e-cigs that represent devices producing different amounts of e-cig aerosols. The tests were performed using two different puff topography regimes to investigate the effect of puff flow rate on carbonyl collection efficiency. Carbonyls emitted from the e-cigs were collected using I-I (two impingers in series), C (a single DNPH cartridge), and DF-C (a DNPH filter followed by a DNPH cartridge). Samples were analyzed using high-performance liquid chromatography coupled with photodiode array detector. Results: Measured carbonyl levels varied between the three methods. For both devices, the highest values were measured with C and DF-C. Results from the 'pod' device measured with I-I were comparable with the other methods, but lower than the other two methods for the 'mod' device. For example, 1 LPM 'mod' acetaldehyde emissions measured with C (0.09 ± 0.02 µg/puff) and DF-C (0.14 ± 0.09 µg/puff) were significantly higher (p = 0.06 and 0.04, respectively) than I-I method (0.05 ± 0.02 µg/puff). Discussion: The likely cause for the underestimation by the I-I method is the inefficient collection of particle phase bound carbonyls by the impingers and, possibly, wall losses in the inlet of the impinger. Based on our results, C provides the best approach for carbonyl collection in e-cig aerosols, while I-I that is used in the standard testing method can underestimate carbonyl emissions when measuring high concentration aerosols such as those produced by 'mod' devices.