Custom 3D-printed split-type triflange implants for severe acetabular defects: mid-term clinical outcomes and biomechanical insights from finite element analysis.

Yu Guo, Dehong Feng, Xiaofeng Gu, Ling Wang, Yujian Ding, Yi Liu, Jialin Qin

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yu GuoDepartment of Orthopedics, The Affiliated Wuxi People's Hospital of Nanjing Medical University, Wuxi People's Hospital, Wuxi Medical Center, Nanjing Medical University, Wuxi, China.
Dehong FengDepartment of Orthopedics, The Affiliated Wuxi People's Hospital of Nanjing Medical University, Wuxi People's Hospital, Wuxi Medical Center, Nanjing Medical University, Wuxi, China.
Xiaofeng GuDepartment of Orthopedics, The Affiliated Wuxi People's Hospital of Nanjing Medical University, Wuxi People's Hospital, Wuxi Medical Center, Nanjing Medical University, Wuxi, China.
Ling WangDepartment of Orthopedics, The Affiliated Wuxi People's Hospital of Nanjing Medical University, Wuxi People's Hospital, Wuxi Medical Center, Nanjing Medical University, Wuxi, China.
Yujian DingDepartment of Orthopedics, The Affiliated Wuxi People's Hospital of Nanjing Medical University, Wuxi People's Hospital, Wuxi Medical Center, Nanjing Medical University, Wuxi, China.
Yi LiuDepartment of Orthopedics, The Affiliated Wuxi People's Hospital of Nanjing Medical University, Wuxi People's Hospital, Wuxi Medical Center, Nanjing Medical University, Wuxi, China.
Jialin QinDepartment of Orthopedics, The Affiliated Wuxi People's Hospital of Nanjing Medical University, Wuxi People's Hospital, Wuxi Medical Center, Nanjing Medical University, Wuxi, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Paprosky 3B acetabular defects challenge revision total hip arthroplasty (THA) due to conventional techniques' high failure rates. This study evaluates midterm outcomes and biomechanical performance of 3D-printed split-type triflange acetabular cups for Paprosky 3B defects. Materials and methods: From 02/01/2017 to 10/30/2021, we retrospectively assessed 14 patients with Paprosky 3B defects using 3D-printed split-type triflange cups. Preoperative CT-based 3D models guided implant design with porous surfaces and optimized screw fixation. Clinical outcomes were assessed via Harris Hip Score (HHS) and Oxford Hip Score (OHS). Radiographic parameters and implant stability were analyzed. Biomechanical characteristics were evaluated through finite element analysis (FEA) under physiological loads representing single-leg stance, walking, and jogging (700N, 2800N, and 4200N). Results: At mean 74.2-month follow-up, HHS improved from 31.9 ± 8.5 to 82.9 ± 5.9 (p < 0.05) and OHS from 7.6 ± 2.3 to 35.4 ± 3.1 (p < 0.05). Anatomical hip center restoration was achieved with comparable postoperative and contralateral rotation center measurements. Radiographic analysis confirmed stable fixation in all cases without loosening. FEA revealed distinct biomechanical behavior between bone models. In both normal and osteoporotic models, stress concentrated at the superior flange screw fixation site and the superior acetabular rim. Under 700N loading, interfacial micromotion at all measurement points (P1-P3) remained below the 40 μm threshold for osseointegration. However, at higher loads (2800N and 4200N), P1 micromotion significantly exceeded this critical threshold in both models, reaching 122.861 μm and 131.244 μm respectively at maximum loading, while P2 and P3 maintained acceptable levels. Conclusion: Custom 3D-printed split-type triflange prostheses achieve excellent midterm functional restoration and biomechanical stability in Paprosky 3B defects. Key advantages include precise hip rotation center reconstruction, favorable stress distribution, and reduced intraoperative morbidity. Early partial weight-bearing is safe, though high-impact activities should await radiographic confirmation of osseointegration. Long-term validation of durability is warranted.

Indexed as

3D-printedacetabular defectfinite element analysisrevisionsplit-typetriflange cup

Identifiers

PMID41383719
PMCPMC12689546

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.