ArticleWorld journal of urology2025
Smartphone-AI videouroflowmetry evaluation (SAVE study): a concordance study with standard uroflowmetry.
Article in World journal of urology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo develop and validate a novel, hardware-free, smartphone-based video uroflowmetry system powered by Artificial Intelligence (AI-VUF), by comparing its diagnostic accuracy against standard weight-based uroflowmetry in male patients with lower urinary tract symptoms (LUTS), as part of the SAVE (Smartphone-AI Videouroflowmetry Evaluation) Study.
methodsA prospective study was conducted involving 103 male patients aged 48–79 years with LUTS. Each participant underwent standard weight-sensor uroflowmetry and simultaneous video recording of voiding using a smartphone. A proprietary AI algorithm was employed to extract the maximum flow rate (Qmax), while voided volume was visually estimated by an independent expert blinded to the results of standard uroflowmetry. Agreement between methods was assessed using Lin’s concordance correlation coefficient (CCC), Bland–Altman plots, absolute percentage error (APE), and responsiveness indices.
resultsAI-VUF showed near-perfect concordance with standard uroflowmetry: CCC was 0.968 for Qmax and 0.992 for voided volume. Mean difference in Qmax was 0.04 mL/s; median APE was 4.0%. Bland–Altman analysis revealed narrow limits of agreement (– 3.66 to + 3.74 mL/s). No significant proportional bias was detected. The system required no calibration and functioned solely on consumer-grade smartphones.
conclusionThis pilot SAVE study demonstrates that AI-assisted videouroflowmetry via smartphone achieves diagnostic performance comparable to standard uroflowmetry. This method offers a promising, scalable solution for remote or office-based assessment of voiding function, with potential to improve access to urological diagnostics.
Indexed as
Identifiers
41381961What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.