Evidence map›Paper›PMID 41377876›Full record

ArticleGland surgery2025

Safety and efficacy of robot-assisted latissimus dorsi flap harvesting for immediate partial breast reconstruction following breast-conserving surgery.

Seokwon Lee

Abstract read
In one paragraph

Article in Gland surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Seokwon LeeDepartment of Surgery, Biomedical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Republic of Korea.ORCID https://orcid.org/0000-0002-0816-9156

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This investigation assesses the safety and practicality of using robotic assistance for harvesting the latissimus dorsi muscle flap (LDMF) for immediate reconstruction after breast-conserving surgery in breast cancer patients. A retrospective analysis was conducted on the medical records of 27 women who underwent immediate reconstruction using robot-assisted LDMF harvesting at our hospital between August 2019 and April 2024. Participants in this study had a mean age of 47.6±8.7 years. The average amount of breast tissue removed, encompassing the tumor, was 133.2±53.0 g. Tumors were most commonly found in the upper outer quadrant, accounting for 37% of cases. The total time required to complete breast-conserving surgery, lymph node evaluation or dissection, robot-assisted LDMF harvest, and subsequent breast reconstruction was, on average, 459.1±120.8 minutes. The average time for robot docking was 30 minutes, with a mean flap harvesting time of 201.1±74.7 minutes. Aside from seroma formation at the donor site, there were no other complications or delays in starting adjuvant treatment. No locoregional or systemic recurrence was observed over the mean follow-up period of 31.8±13.1 months. Overall patient-reported satisfaction was excellent or good in 88.9% of cases, with particularly high satisfaction regarding the absence of scarring. Robot-assisted LDMF harvesting is a safe and effective option for partial breast reconstruction, providing high patient satisfaction and minimal scarring.

Indexed as

breast-conserving surgerybreast reconstructionda Vincilatissimus dorsi muscle flap (LDMF)Robot-assisted surgery

Identifiers

PMID41377876
PMCPMC12685769

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.