ArticleJournal of craniovertebral junction & spine
Adverse events associated with the Barricaid annular closure device: An analysis of the FDA MAUDE Database.
Article in Journal of craniovertebral junction & spine. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 1 synthesis or guideline pooled it.
- The efficacy and safety of annulus fibrosus suture as adjuvant therapy for lumbar disc herniation: a systematic review and meta-analysis.Frontiers in bioengineering and biotechnology · 2025Pooled it
- Single-Step Extrusion Printing of Microgrooved Annulus Fibrosus Scaffolds via Patterned Nozzles.Journal of functional biomaterials · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: The Barricaid annular closure device (Intrinsic Therapeutics, Inc., Woburn, MA) functions to prevent reherniation in patients undergoing primary discectomies for L4-L5 or L5-S1 disc herniation with large annular defects. However, there are limited investigations assessing patient safety. This study analyzed clinical data on device malfunctions and adverse events to inform potential areas for improvements. Methods: Adverse event reports related to the Barricaid device filed from January 1, 2020, to February 28, 2025, were retrieved from the U. S. Food and Drug Administration Manufacturer and User Facility Device Experience database. Event date, device type, device malfunction, and adverse event were recorded. Results: 101 adverse event reports were included in this study. The most common malfunction was device migration (30.7%), followed by unsuccessful implantations (26.7%), which were addressed either intraoperatively (22.8%) or in revision surgeries (4.0%). Reherniation was the most frequently reported device-related adverse event (36.6%), while other postoperative complications were anticipated following spine surgeries that involved implants. Revision surgeries were performed in 67 reports following discoveries of device malfunction and/or adverse events (66.3%). 46 reoperations involved partial or complete device removal (45.5%). Conclusion: Device malfunctions and adverse events inform the importance of careful patient selection, meticulous device handling, and improved device design in enhancing patient safety and outcomes. Patients with frailty, comorbidities, or postimplant adverse events could be subject to increased morbidity and reoperations. Continued postmarketing improvements are needed to mitigate device malfunctions and adverse events.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.