Evidence map›Paper›PMID 41377828›Full record

ArticleJournal of craniovertebral junction & spine

Evaluating accuracy in robotic-assisted thoracolumbar pedicle screw placement: Insights from a single-center study of 410 patients.

Abhishek Soni, Vidyadhara Srinivasa, Akhil Xavier Joseph, Balamurugan Thirugnanam, Alia Vidyadhara

Abstract read
In one paragraph

Article in Journal of craniovertebral junction & spine. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Abhishek Soni *Department of Spine Surgery, Manipal Institute of Robotic Spine Surgery, Manipal Hospital, Bengaluru, Karnataka, India.
Vidyadhara Srinivasa *Department of Spine Surgery, Manipal Institute of Robotic Spine Surgery, Manipal Hospital, Bengaluru, Karnataka, India.
Akhil Xavier JosephDepartment of Spine Surgery, Manipal Institute of Robotic Spine Surgery, Manipal Hospital, Bengaluru, Karnataka, India.
Balamurugan ThirugnanamDepartment of Spine Surgery, Manipal Institute of Robotic Spine Surgery, Manipal Hospital, Bengaluru, Karnataka, India.
Alia VidyadharaDepartment of Spine Anesthesia, Manipal Institute of Robotic Spine Surgery, Manipal Hospital, Bengaluru, Karnataka, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Study Design: A single-center prospective study evaluating the accuracy and factors influencing robotic-assisted pedicle screw placement in the thoracolumbar spine. Objectives: To assess the accuracy of robotic-assisted pedicle screw placement in thoracolumbar spine surgeries and to analyze the factors that enhance or hinder the precision of robotic systems in a single-center setting. Summary of Background Data: Robotic systems are significant advancement in spinal surgery, offering added advantage in pedicle screw placement compared to conventional methods such as freehand, fluoroscopy-guided, and computer-aided navigation (CAN)-guided techniques. Robots combine CAN with a stable mechanical arm, ensuring accurate placement along preplanned trajectories, particularly advantageous in complex anatomies. Methods: A total of 410 patients who underwent robotic-assisted thoracolumbar spine surgery were included in the study. Pedicle screws were placed with robotic assistance using an optimized workflow. Screw placement accuracy was evaluated using the Gertzbein-Robbins classification, with screws graded A and B considered clinically acceptable. Results: Of the 2600 screws placed, 99.2% were clinically acceptable (93.4% Grade A and 5.8% Grade B), with only 0.8% exhibiting breaches requiring revision. Lateral breaches were the most common (59.1%). Robotic system usage averaged 20.6 min, with an average time of 3.8 min per screw insertion. Postoperative outcomes included a mean Visual Analog Scale pain score of 7.3 and an average hospital stay of 4.7 days. Conclusions: Robotic-assisted pedicle screw placement using the Mazor X system demonstrated high accuracy and minimal revision rates. Robotic integration reduces complications and streamlines workflows, improving patient safety and advancing spine surgery standards.

Indexed as

Mazor X systempedicle screw placementrobotic-assisted surgerysurgical accuracythoracolumbar spine