Evidence map›Paper›PMID 41377632›Full record

ArticleCirculation reports2025

Placement of the Coronary Sinus Catheter via the Right Cubital Vein During Atrial Fibrillation Ablation.

Kohei Iwasa, Masato Okada, Koji Tanaka, Yuko Hirao, Naoko Miyazaki, Heitaro Watanabe, Yoshitaka Iwanaga, Atsunori Okamura, Yasushi Sakata, Nobuaki Tanaka

Abstract read
In one paragraph

Article in Circulation reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Kohei IwasaCardiovascular Center, Sakurabashi Watanabe Advanced Healthcare Hospital Osaka Japan.
Masato OkadaCardiovascular Center, Sakurabashi Watanabe Advanced Healthcare Hospital Osaka Japan.
Koji TanakaCardiovascular Center, Sakurabashi Watanabe Advanced Healthcare Hospital Osaka Japan.
Yuko HiraoCardiovascular Center, Sakurabashi Watanabe Advanced Healthcare Hospital Osaka Japan.
Naoko MiyazakiCardiovascular Center, Sakurabashi Watanabe Advanced Healthcare Hospital Osaka Japan.
Heitaro WatanabeCardiovascular Center, Sakurabashi Watanabe Advanced Healthcare Hospital Osaka Japan.
Yoshitaka IwanagaCardiovascular Center, Sakurabashi Watanabe Advanced Healthcare Hospital Osaka Japan.
Atsunori OkamuraCardiovascular Center, Sakurabashi Watanabe Advanced Healthcare Hospital Osaka Japan.
Yasushi SakataDepartment of Cardiovascular Medicine, Osaka University Graduate School of Medicine Osaka Japan.
Nobuaki TanakaCardiovascular Center, Sakurabashi Watanabe Advanced Healthcare Hospital Osaka Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Electrode catheter placement into the coronary sinus (CS) is critical for electrophysiologic studies. Although central venous approaches (e.g., internal jugular or subclavian) are well documented, peripheral venous approaches like the cubital vein are not. This study evaluated the feasibility and safety of CS catheter placement via the right cubital vein during atrial fibrillation (AF) ablation. Methods and Results: Of 1,363 consecutive patients who underwent first-time AF ablation at Sakurabashi Watanabe Advanced Healthcare Hospital between January 2019 and December 2021, 1,274 underwent at least 1 right cubital vein puncture attempt. The success rate, causes of failure, and complications were analyzed. CS catheters were successfully placed via the right cubital vein in 1,214 (95.3%) patients, whereas placements were unsuccessful in 60 (4.7%) patients. Although older patients were more likely to experience unsuccessful placements, there were no significant differences in other baseline characteristics between the 2 groups. Unsuccessful placements were attributed to failure in venipuncture or sheath insertion (n=49) and failure to advance the CS catheter through the vein (n=11). No major complications were reported. Conclusions: CS catheter placement via the right cubital vein demonstrated high feasibility and safety, with a 95% success rate and minimal complications. This approach offers a practical and technically straightforward alternative for placing CS catheters, particularly in patients with adequate vein development.

Indexed as

Atrial fibrillationCatheter ablationCoronary sinusCubital veinElectrode catheter

Identifiers

PMID41377632
PMCPMC12688425

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.