Evidence map›Paper›PMID 41376867›Full record

ArticleStructural heart : the journal of the Heart Team2026

The Impact of Prosthesis-Patient Mismatch on Bioprosthetic Valve Durability After Transcatheter Aortic Valve Replacement.

Revathy Sampath-Kumar, Erika Padilla, David Torres Barba, Niki Aramburo, Ori Ben-Yehuda, Ehtisham Mahmud

Abstract read
In one paragraph

Article in Structural heart : the journal of the Heart Team, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Prosthesis-Patient Mismatch in All-Comer Patients Undergoing Newer-Generation Self-Expanding Transcatheter Aortic Valve Replacement.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
    Article
  2. Article
  3. Letter to the Editor Response.Structural heart : the journal of the Heart Team · 2026
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Revathy Sampath-KumarDivision of Cardiovascular Medicine, University of California San Diego, La Jolla, California, USA.
Erika PadillaDivision of Cardiovascular Medicine, University of California San Diego, La Jolla, California, USA.
David Torres BarbaDivision of Cardiovascular Medicine, University of California San Diego, La Jolla, California, USA.
Niki AramburoDivision of Cardiovascular Medicine, University of California San Diego, La Jolla, California, USA.
Ori Ben-YehudaDivision of Cardiovascular Medicine, University of California San Diego, La Jolla, California, USA.
Ehtisham MahmudDivision of Cardiovascular Medicine, University of California San Diego, La Jolla, California, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Prosthesis-patient mismatch (PPM) is associated with structural valve deterioration after surgical aortic valve replacement. Limited evidence exists regarding its impact on hemodynamic valve deterioration (HVD) and bioprosthetic valve failure (BVF) following transcatheter aortic valve replacement (TAVR). Methods: Patients who underwent TAVR from 2013 to 2022 at UC San Diego Health with echocardiographic follow-up were retrospectively analyzed. PPM, determined by measured indexed effective orifice area, and outcomes of moderate or severe HVD and BVF were defined per Valve Academic Research Consortium 3 guidelines. Fine and Gray regression, with all-cause death as a competing risk, was used to compare the cumulative incidence of outcomes in patients with and without PPM. Results: A total of 555 patients (38.7% female, median age 81 years, median Society of Thoracic Surgeons risk score 4.2%, 96.8% balloon-expandable valves) were included. PPM occurred in 66 (11.9%) patients and was associated with higher initial post-implant mean gradient (15 mmHg IQR: 10-22 vs. 11 mmHg IQR: 8-15; Conclusions: In this single-center cohort, PPM was associated with an over two-fold increased risk of moderate or severe HVD and an over four-fold increased risk of BVF following TAVR, emphasizing the importance of pre-implant prevention.

Indexed as

Hemodynamic valve deteriorationProsthesis-patient mismatchTranscatheter aortic valve replacement

Identifiers

PMID41376867
PMCPMC12686684

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.