Evidence map›Paper›PMID 41376440›Full record

ArticleClinics in shoulder and elbow2025

Biomechanical evaluation of patch augmentation in a rotator cuff repair model using a porcine flexor digitorum profundus tendon: influence of knot tying and time-zero stability.

Sung-Min Rhee, Chul-Hyun Cho, Minsung Kim, Hyo-Young Lee, Ji Hwan Kim, Yeon Soo Lee, Chris Hyunchul Jo

Abstract read
In one paragraph

Article in Clinics in shoulder and elbow, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sung-Min RheeDepartment of Orthopedic Surgery, Kyung Hee University College of Medicine, Seoul, Korea.
Chul-Hyun ChoDepartment of Orthopedic Surgery, Keimyung University Dongsan Hospital, Keimyung University School of Medicine, Daegu, Korea.
Minsung KimDepartment of Orthopedic Surgery, Kyung Hee University College of Medicine, Seoul, Korea.
Hyo-Young LeeDepartment of Orthopedic Surgery, Busan Paik Hospital, Busan, Korea.
Ji Hwan KimDepartment of Orthopedic Surgery, Hanyang University Hospital, Hanyang University College of Medicine, Seoul, Korea.
Yeon Soo LeeDepartment of Biomedical Rehabilitation Engineering, College of Medical Science, Catholic University of Daegu, Gyeongsan, Korea.
Chris Hyunchul JoDepartment of Orthopedic Surgery, SMG-SNU Boramae Medical Center, Seoul National University College of Medicine, Seoul, Korea.

Funding

Korean Shoulder and Elbow Society Translational Research Committee
6 · The paper itself

Abstract

backgroundThis study evaluates the biomechanical effects of acellular dermal matrix (ADM) patch augmentation in a rotator cuff repair model and determines the effect of medial knot tying on time-zero stability.

methodsA biomechanical study was conducted using a porcine flexor digitorum profundus tendon model. Eighteen specimens were assigned to three groups: non-patched repair with medial row knot tying (n=5), patch-augmented repair without medial row knot tying (n=4), and patch-augmented repair with medial row knot tying (n=4). All repairs were performed using a standardized double-row suture bridge technique. Biomechanical testing assessed elongation, strain, load to failure, and construct stiffness at time zero.

resultsPatch augmentation without medial row knot tying resulted in significantly greater tendon elongation (12.9±6.5 mm) than nonpatched repairs (5.0±5.3 mm, P=0.016) and patch-augmented repairs with medial row knot tying (4.4±4.4 mm, P=0.027). Similarly, strain was significantly higher in the patch-augmented group without medial knot tying (75.8%±42.9%) than in the non-patched repair (35.2%±38.9%, P=0.028) and patch-augmented repair with medial knot tying groups (29.1%±28.9%, P=0.052). However, load to failure did not differ significantly among the groups (P>0.05).

conclusionsADM patch augmentation did not enhance time-zero mechanical strength in the tested conditions, though biomechanical advantages might emerge after integration to the tendon. In addition, patch augmentation without medial row knot tying showed the highest elongation and strain among groups, potentially reducing the stability of the repair. Level of evidence: V, controlled laboratory study.

Indexed as

Acellular dermal matrixBiomechanical stabilityKnotting techniquesPatch augmentationRotator cuff repair

Identifiers

PMID41376440
PMCPMC12698353

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.