ArticleMolecules (Basel, Switzerland)2025
Influence of Electrode Polishing Protocols, Potentiostat Models, and LOD Calculation Methods on the Electroanalytical Performance of SWV Measurements at Glassy Carbon Electrodes.
Article in Molecules (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
The aim of this research is to present the extent to which the basic elements used in electrochemical measurements affect the results of electroanalytical procedures. Measurements were carried out using the square wave voltammetric technique on a glassy carbon electrode, and the recorded analytical signal corresponded to a model redox system. One of the objectives of the study was to illustrate the impact of using potentiostats from different manufacturers, as well as the variations observed among different models within the same brand. These models exhibited notable differences in both cost and advanced electrochemical measurement capabilities. The mechanical cleaning method for the solid disk electrode surface was also taken into consideration. Three different polishing motion types were tested, together with the number of repetitions. It was revealed that polishing motion significantly influences the electroactive surface area of the working electrode, as well as the repeatability of the measurements. The research showed that the largest electroactive surface area and the best repeatability of parameters are achieved when polishing is performed by drawing an 8-type motion on the polishing pad. The obtained results confirmed that the equipment and polishing applied in research have a greater than previously assumed impact on the statistical parameters characterizing the analytical procedure, for example, the limit of detection (LOD) or the dynamic range of the calibration curve. Both analyzed parameters have a significant impact on the quality of the statistical parameters describing derived analytical procedures. Finally, it was shown that significantly different statistical parameters can be obtained from the same set of data using various approaches for LOD estimation, with discrepancies reaching up to two orders of magnitude.