ArticleSensors (Basel, Switzerland)2025
Semi-Quantitative On-Site Microfluidic Assay to Detect 11-Nor-9-carboxy-delta 9-Tetrahydrocannabinol (THC-COOH) in Urine.
Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
Abstract
The rapid detection of 11-nor-9-carboxy-delta-9-tetrahydrocannabinol (THC-COOH), a primary cannabis metabolite, is critical for forensic and workplace drug testing. However, conventional immunoassays often lack sensitivity and objectivity. We developed a portable lateral flow immunoassay device with a microfluidic cartridge and fluorescent reader for the semi-quantitative detection of THC-COOH in urine. A test-to-reference fluorescence ratio was employed to mitigate matrix effects and ensure objective results. The device was validated for accuracy, repeatability, and stability using spiked urine samples and compared against validated LC-MS/MS results on 100 authentic urine samples (50 positive and 50 negative). At a cutoff of 20 ng/mL, the device achieved 100% sensitivity and specificity, with repeatability and reproducibility CVs of below 15%. The cutoff index (COI) strongly correlated with LC-MS/MS results (R
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.