Evidence map›Paper›PMID 41374488›Full record

ArticleSensors (Basel, Switzerland)2025

Reconstruction of Respiratory Flow from an Impedance-Based Contactless Sensor System.

Moritz Bednorz, Jan Ringkamp, Lara-Jasmin Behrend, Philipp Lebhardt, Jens Langejürgen

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Moritz BednorzFraunhofer Institute for Manufacturing Engineering and Automation IPA, Theodor-Kutzer-Ufer 1-3 (Cubex41), 68167 Mannheim, Germany.ORCID 0000-0002-4981-5732
Jan RingkampFraunhofer Institute for Manufacturing Engineering and Automation IPA, Theodor-Kutzer-Ufer 1-3 (Cubex41), 68167 Mannheim, Germany.ORCID 0000-0003-1683-9225
Lara-Jasmin BehrendFraunhofer Institute for Manufacturing Engineering and Automation IPA, Theodor-Kutzer-Ufer 1-3 (Cubex41), 68167 Mannheim, Germany.
Philipp LebhardtFraunhofer Institute for Manufacturing Engineering and Automation IPA, Theodor-Kutzer-Ufer 1-3 (Cubex41), 68167 Mannheim, Germany.ORCID 0009-0004-0987-6989
Jens LangejürgenFraunhofer Institute for Manufacturing Engineering and Automation IPA, Theodor-Kutzer-Ufer 1-3 (Cubex41), 68167 Mannheim, Germany.ORCID 0000-0002-9694-3040

Funding

Ministerium für Wirtschaft, Arbeit und Wohnungsbau Baden-Württemberg Without subsidy number. File number: 35-4223.10/13
6 · The paper itself

Abstract

Conventional respiratory monitoring is often invasive, while most non-contact technologies like radar or cameras are limited to estimating respiratory rate, failing to reconstruct the detailed waveform of the respiratory flow itself. This gap limits their clinical utility for advanced diagnostics. We introduce a novel system that bridges this gap by combining a contactless, impedance-based sensor (the Thoraxmonitor) with a dedicated machine learning framework to directly reconstruct the full respiratory flow signal. Operating at 433 MHz, the system's antenna array detects subtle changes in thoracic impedance, which are then translated into a quantitative flow signal by a Multilayer Perceptron Regressor. Based on data from 17 subjects benchmarked against a gold-standard flowmeter, our system accurately detected 98% of respiratory cycles. It achieved remarkable precision in timing respiratory events, with mean deviations of + 60 ms (±79 ms) for inspiration and + 50 ms (±63 ms) for expiration, making it suitable for time-critical applications. While a systematic bias in absolute tidal volume prediction currently limits inter-subject comparisons, the system excels at tracking relative intra-subject changes. Crucially, our model quantifies its own reliability, providing an intrinsic self-assessment mechanism. This work demonstrates a significant step beyond simple rate detection towards comprehensive, comfortable, and reliable respiratory analysis in clinical and everyday settings.

Indexed as

Electric ImpedanceMonitoring, PhysiologicRespiratory RateAdultFemaleHumansMachine LearningMaleRespirationSignal Processing, Computer-Assistedcontactless sensorISM radio bandmachine learningmonitoringnon-invasiverespiratory signal detectionsoft sensor

Identifiers

PMID41374488
PMCPMC12694511

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.