Evidence map›Paper›PMID 41374214›Full record

ArticleMaterials (Basel, Switzerland)2025

The Effect of Graphene Oxide Deposited on Titanium Surface on Structural, Corrosion, and Biological Properties.

Kamila Narojczyk, Barbara Nasiłowska, Agata Lange, Marta Kutwin, Sławomir Jaworski, Łukasz Krzowski, Wiktoria Kasprzycka, Piotr Olejnik, Maciej Chrunik, Aneta Bombalska and 1 more

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Kamila NarojczykDoctoral School, Military University of Technology, gen. S. Kaliskiego 2, 00-908 Warsaw, Poland.ORCID 0009-0003-4849-4783
Barbara NasiłowskaInstitute of Optoelectronics, Military University of Technology, gen. S. Kaliskiego 2, 00-908 Warsaw, Poland.ORCID 0000-0003-0960-5260
Agata LangeDepartment of Nanobiotechnology, Institute of Biology, Warsaw University of Life Sciences, Ciszewskiego 8, 02-786 Warsaw, Poland.ORCID 0000-0003-1523-083X
Marta KutwinDepartment of Nanobiotechnology, Institute of Biology, Warsaw University of Life Sciences, Ciszewskiego 8, 02-786 Warsaw, Poland.ORCID 0000-0001-7059-7875
Sławomir JaworskiDepartment of Nanobiotechnology, Institute of Biology, Warsaw University of Life Sciences, Ciszewskiego 8, 02-786 Warsaw, Poland.ORCID 0000-0002-4619-941X
Łukasz KrzowskiInstitute of Optoelectronics, Military University of Technology, gen. S. Kaliskiego 2, 00-908 Warsaw, Poland.ORCID 0000-0001-8966-7730
Wiktoria KasprzyckaInstitute of Optoelectronics, Military University of Technology, gen. S. Kaliskiego 2, 00-908 Warsaw, Poland.ORCID 0000-0002-2796-2555
Piotr OlejnikDepartment of Physics and Biophysics, Warsaw University of Life Sciences (SGGW), 159 Nowoursynowska Street, 02-776 Warsaw, Poland.ORCID 0000-0003-4966-4134
Maciej ChrunikInstitute of Applied Physics, Military University of Technology, gen. S. Kaliskiego 2, 00-908 Warsaw, Poland.ORCID 0000-0002-2369-3992
Aneta BombalskaInstitute of Optoelectronics, Military University of Technology, gen. S. Kaliskiego 2, 00-908 Warsaw, Poland.ORCID 0000-0003-0417-7340
Zdzisław BogdanowiczFaculty of Mechanical Engineering, Military University of Technology, gen. S. Kaliskiego 2, 00-908 Warsaw, Poland.ORCID 0000-0002-4514-8610

Funding

Military University of Technology in Warsaw UGB 22-016/2025Military University of Technology in Warsaw UGB 531-000082-W600-22
6 · The paper itself

Abstract

The article presents the results of structural, corrosion, microbiological, biological, and genotoxicity studies on the effect of graphene oxide deposited on a flat titanium foil surface, intended for use, in general, implantology and other medical applications. The methodology of graphene oxide (GO) deposition involved a surface cleaning process combined with RF plasma activation, followed by the application of a thin layer of dispersed aqueous GO suspension using a spin coater. The graphene oxide layer was uniformly deposited on the surface, which was confirmed by SEM imaging. Corrosion studies were carried out in an electrochemical cell filled with a buffered solution prepared to mimic the composition of physiological intracellular fluids. It was demonstrated that the deposition of graphene oxide on the titanium surface limited the access of electrolyte and oxygen. Surface activation and deposition of the aqueous graphene oxide suspension contributed to improved adhesion, condition, growth, and proliferation of fibroblast cell lines Hs 895.T and Hs 895.Sk. The inhibition zone analysis revealed a bacteriostatic effect against

Indexed as

graphene oxidehuman skin fibroblast cell line Hs 895.Skhuman skin melanoma cell line Hs 895.Timplantstitanium

Identifiers

PMID41374214
PMCPMC12692922

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.