Evidence map›Paper›PMID 41373114›Full record

ArticleJournal of applied clinical medical physics2025

High-accuracy quality control method of CT system couch tops for treatment planning via an advanced 3D coordinate measuring machine.

Ryuichi Yada, Masataka Sakamoto, Naoya Kurino, Yusuke Ueshima, Tianyuan Wang, Iori Sumida, Katsumasa Nakamura

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ryuichi YadaDepartment of Regional Medical Management Studies, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan.ORCID https://orcid.org/0009-0005-7563-8273
Masataka SakamotoDepartment of Radiology, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan.
Naoya KurinoDepartment of Radiology, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan.
Yusuke UeshimaRegional Creative Education Center, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan.ORCID https://orcid.org/0009-0006-6256-3249
Tianyuan WangDepartment of Medical Physics, Kobe Proton Center, Kobe, Hyogo, Japan.
Iori SumidaMarketing and Clinical Solutions, Accuray Japan K.K., Chiyoda-ku, Tokyo, Japan.
Katsumasa NakamuraDepartment of Radiation Oncology, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan.

Funding

2023-2024Japanese Society for Radiation Oncology
6 · The paper itself

Abstract

backgroundQuality control (QC) methods for computed tomography (CT) systems used in treatment planning have not been updated since the release of the Task Group (TG) 66 report by the American Association of Physicists in Medicine (AAPM) in 2003. Conventional QC methods for CT systems fail to fulfill the requirements of high-precision radiation therapy. Moreover, because the geometric accuracy of CT systems can affect the accuracy of radiation therapy, which is particularly critical in high-precision radiation therapy, a highly accurate QC method is required. PURPOSE: This study aimed to develop a high-accuracy QC method for CT system couch tops suitable for high-precision radiation therapy by utilizing a wide-area three-dimensional (3D) coordinate measuring machine (3D-CMM), a type of laser tracker.

methodsWe used a 3D-CMM, which includes a wireless probe and a camera unit, focusing on a SOMATOM go.Open Pro CT system. The system was set up in accordance with the reference method outlined in the AAPM TG66 report guidelines. The initial phase verified the accuracy of 3D-CMM measurement within a CT room using a micrometer. Subsequently, a novel continuous measurement method was developed to enable the real-time tracking of the couch-top displacement during travel. This new method was evaluated against the standard manual measurement method. Measurements were performed at 0.1 s intervals at various index positions on the couch top, with and without added weight to simulate the presence of a patient. The gathered data were analyzed to assess the couch-top displacement, horizontality and orthogonality relative to the imaging plane, providing a comprehensive evaluation of the stability and alignment of the couch top.

resultsThe difference between the micrometer and measured shifts peaked at 0.08 mm. The continuous measurements agreed with the standard measurements within one standard deviation of the three measurements. The maximum displacements of the couch top were 5.23 and 2.00 mm in the vertical axis, with and without a weight load, respectively. There were differences in the displacement at each measurement point. In the lateral axis, the maximum displacements were 2.05 and 2.09 mm with and without a weight load, respectively. The maximum displacement in the imaging plane was observed at approximately half the distance traveled by the couch top. As the couch top traveled, the horizontal angle in the imaging plane of the couch top varied from 0.06° to 0.07° and 0.25° without a weight load and from 0.09° to 0.21° and 0.34° with a weight. The orthogonal angles of the couch top varied from 0.07° to 0.08° and 0.14° without a weight load and from 0.05° to 0.23° and 0.46° with a weight.

conclusionsThe developed QC method for the couch tops of CT systems can evaluate the displacement of the couch top and its horizontality and orthogonality to the imaging plane with detailed submillimeter and subdegree accuracy levels. The high-accuracy QC of CT systems can improve the accuracy of irradiation in radiation therapy.

Indexed as

Tomography, X-Ray ComputedImaging, Three-DimensionalQuality ControlRadiotherapy Planning, Computer-AssistedCT systemhigh‐precision radiation therapyquality control methodthree‐dimensional coordinate measuring machine

Identifiers

PMID41373114
PMCPMC12695700

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.