Evidence map›Paper›PMID 41370283›Full record

ArticlePloS one2025

Increased inflammation and oxidative stress caused by accumulated metal particle exposure among metro station staff.

Zukun Wang, Junjie Liu, Yijun Song, Mingyao Yao, Shihao Wen, Wenzhe Shang, Mingtong He, Yushuang Wang, Junjie He

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Zukun WangTianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, China.
Junjie LiuTianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, China.ORCID https://orcid.org/0000-0001-7060-6663
Yijun SongDepartment of Intensive Care Medicine, State Key Laboratory of Experimental Hematology, National Clinical Research Center for Blood Diseases, Haihe Laboratory of Cell Ecosystem, Institute of Hematology and Blood Diseases Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, China.
Mingyao YaoTianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, China.
Shihao WenTianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, China.
Wenzhe ShangTianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, China.
Mingtong HeTianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, China.
Yushuang WangTianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, China.
Junjie HeTianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Metro is a significant part of world transport, delivering over 58 billion passengers annually. Train operation processes generated PM rich in heavy metals in the station, but the natural ventilation underground is poor leading to a high PM exposure indoors. Though PM pollution in metro stations was reported widely, there is limited evidence of the adverse health effect of metro station PM. This study collected urinary samples from 74 metro station staff from three different metro stations in Tianjin for 8-OHdG, IL-6, MDA, GSH and T-AOC tests using commercial kits. PM samples were collected for metal composition tests using ICP-MS and oxidative potential test using DTT method. The average PM2.5 concentration was 31.5 ± 12.4 μg/m3, meeting the Standard for indoor air quality in China. However, the indoor concentrations of Zn, Cu, Mn, and Fe were ten times higher than those in the ambient air, inferring a higher exposure level of metal particles. Urinary 8-OHdG, MDA, and IL-6 of senior employees (length of service in the metro station > 5 years) were significantly higher than new employees but not related to age, suggesting a significant influence on individual's inflammation and oxidative stress led by PM exposure. Identified as characteristic elements in the metro stations, Mo and Ni, were also found significantly correlated with urinary IL-6 and GSH. The findings indicates that chronic metal PM exposure in the metro station may induce oxidative stress and inflammation. However, the accumulated PM2.5 concentration showed a poor relation with biomarkers except for IL-6. Accumulated oxidative potential of PM was significantly correlated with urinary IL-6, 8-OHdG, GSH, and T-AOC. This result suggested the accumulated oxidative potential of PM as a better evaluation method of health influence led by PM rather than mass concentration.

Indexed as

Air Pollution, IndoorInflammationMetalsMetals, HeavyOccupational ExposureOxidative StressParticulate MatterRailroads8-Hydroxy-2'-DeoxyguanosineAdultBiomarkersChinaFemaleGlutathioneHumansInterleukin-68-Hydroxy-2'-DeoxyguanosineBiomarkersGlutathioneInterleukin-6MetalsMetals, HeavyParticulate Matter

Identifiers

PMID41370283
PMCPMC12694840

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.