Evidence map›Paper›PMID 41370258›Full record

ArticlePloS one2025

FFO-based controller for 3-phase inverter to reduce power quality problems in PV-integrated microgrid system.

Narisetti Ashok Kumar, M Kiran Kumar, B Srikanth Goud, Joon-Ho Choi, Ch Rami Reddy

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Narisetti Ashok KumarDepartment of Electrical and Electronics Engineering, Koneru Lakshmaiah Education Foundation, Guntur, India.
M Kiran KumarDepartment of Electrical and Electronics Engineering, Koneru Lakshmaiah Education Foundation, Guntur, India.
B Srikanth GoudDepartment of Electrical and Electronics Engineering, School of Engineering, Anurag University, Hyderabad, India.
Joon-Ho ChoiDepartment of Electrical Engineering, Chonnam National University, Gwangju, Korea.ORCID https://orcid.org/0000-0002-0258-1369
Ch Rami ReddyDepartment of Electrical and Electronics Engineering, Vallurupalli Nageswara Rao Vignana Jyothi Institute of Engineering and Technology, Hyderabad, India.ORCID https://orcid.org/0000-0003-1941-0766

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Renewable Energy Sources (RESs) are extensively utilized in the energy sector to meet the present energy demand. As a result of the excessive use of allotted resources, converters must be used numerous times to synchronize the power grid, resulting in low-quality power. The uncertainties resulting from the integration of multiple energy sources were reflected by the distribution system. As microgrids (MGs) transition, the main Power Quality (PQ) issues like voltage unbalancing, voltage swell/sag, poor power factor, power transients appear and Total Harmonic Distortion (THD). Numerous researches studies were going on for reducing PQ issues as well as improving the system reliability under all circumstances, but those models have some impact for attaining a good power flow at the end users. In this study, a microgrid including PVs, wind turbines, and batteries was constructed as a Distributed Energy Resource (DER). To address the aforementioned PQ difficulties, a unique regulating system has been proposed to manage the power flows. The input of the proposed optimal controller was considered as dc voltage, coupling voltage and load current, based on these values, the controller generated a pulse signal of a three-phase inverter to decrease the power supply from PV and wind to maintain a constant frequency and power factor. The optimal problem of the proposed controller was solved through the use of Fennec Fox Optimization (FFO). The performance of the FFO-based controller was analyzed under various PQ issue conditions. The suggested controller's functionality was verified by expanding the microgrid to create a large, three-phase structure. The realistic microgrid's feasibility is verified by the inclusion of demand response, line impedance, and off-nominal scenarios. The proposed model offers 2.2% THD, 50 Hz, 0.8 power factor at a simple microgrid. The proposed model provides well-mitigated performance in any circumstance with a constant frequency and power factor.

Indexed as

Electric Power SuppliesRenewable EnergyElectricityEquipment DesignModels, Theoretical

Identifiers

PMID41370258
PMCPMC12694846

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.