Evidence map›Paper›PMID 41369035›Full record

ArticleACS applied materials & interfaces2025

Mitigating Ion Migration with Alternating Voltage for Stable Perovskite Image Sensors.

Sergey Tsarev, Yuliia Kominko, Kyuik Cho, Lorenzo J A Ferraresi, Gebhard Matt, Kostiantyn Sakhatskyi, Volodymyr Svintozelskyi, Daria Proniakova, Taekwang Jang, Maksym Kovalenko and 1 more

Abstract read
In one paragraph

Article in ACS applied materials & interfaces, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Sergey TsarevLaboratory of Inorganic Chemistry, Department of Chemistry and Applied Biosciences, ETH Zürich, Zürich CH-8093, Switzerland.
Yuliia KominkoLaboratory of Inorganic Chemistry, Department of Chemistry and Applied Biosciences, ETH Zürich, Zürich CH-8093, Switzerland.ORCID 0009-0007-2106-5056
Kyuik ChoLaboratory of Integrated Systems, Department Information Technology and Electrical Engineering, ETH Zürich, Zürich CH-8092, Switzerland.
Lorenzo J A FerraresiLaboratory of Inorganic Chemistry, Department of Chemistry and Applied Biosciences, ETH Zürich, Zürich CH-8093, Switzerland.ORCID 0009-0001-6559-8977
Gebhard MattLaboratory of Inorganic Chemistry, Department of Chemistry and Applied Biosciences, ETH Zürich, Zürich CH-8093, Switzerland.
Kostiantyn SakhatskyiLaboratory of Inorganic Chemistry, Department of Chemistry and Applied Biosciences, ETH Zürich, Zürich CH-8093, Switzerland.ORCID 0000-0003-2384-1665
Volodymyr SvintozelskyiLaboratory of Inorganic Chemistry, Department of Chemistry and Applied Biosciences, ETH Zürich, Zürich CH-8093, Switzerland.
Daria ProniakovaLaboratory of Inorganic Chemistry, Department of Chemistry and Applied Biosciences, ETH Zürich, Zürich CH-8093, Switzerland.
Taekwang JangLaboratory of Integrated Systems, Department Information Technology and Electrical Engineering, ETH Zürich, Zürich CH-8092, Switzerland.
Maksym KovalenkoLaboratory of Inorganic Chemistry, Department of Chemistry and Applied Biosciences, ETH Zürich, Zürich CH-8093, Switzerland.ORCID 0000-0002-6396-8938
Sergii YakuninLaboratory of Inorganic Chemistry, Department of Chemistry and Applied Biosciences, ETH Zürich, Zürich CH-8093, Switzerland.ORCID 0000-0002-6409-0565

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Perovskite photodetectors have emerged as a potential replacement for silicon photodiodes in modern cameras due to their high sensitivity to visible light and ability to be easily integrated into existing electronics. However, the use of perovskite photodetectors in conventional CMOS image sensors requires the application of reverse bias, which can lead to unstable detector performance due to ion migration effects. In this article, we propose a new approach that involves the application of forward voltage pulses to attenuate ion migration while still enabling the capture of photocurrent under reverse bias. Our results show that using this technique after each cycle of signal integration allows for stable operation of perovskite photodetectors for over 180 h, while applying a constant reverse bias leads to degradation within just 10 min. Additionally, we demonstrate stable imaging using alternating voltage and 8 × 8 crossbar arrays of perovskite photodetectors.

Indexed as

alternating biasarraysCMOSion migrationmetal halide perovskitesphotodetectorsstability

Identifiers

PMID41369035
PMCPMC12754746

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.