Evidence map›Paper›PMID 41367633›Full record

ArticleIEEE transactions on computational imaging2025

Convergent Complex Quasi-Newton Proximal Methods for Gradient-Driven Denoisers in Compressed Sensing MRI Reconstruction.

Tao Hong, Zhaoyi Xu, Se Young Chun, Luis Hernandez-Garcia, Jeffrey A Fessler

Abstract read
In one paragraph

Article in IEEE transactions on computational imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Tao HongOden Institute for Computational Engineering and Sciences, University of Texas at Austin, Austin, TX 78712, USA, Department of Radiology, University of Michigan, Ann Arbor, MI 48109, USA.
Zhaoyi XuDepartment of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA.
Se Young ChunDepartment of ECE, INMC & IPAI, SNU, Seoul, 08826, South Korea.
Luis Hernandez-GarciaDepartment of Radiology, University of Michigan, Ann Arbor, MI 48109, USA.
Jeffrey A FesslerEECS Department, University of Michigan, Ann Arbor, MI 48109, USA.

Funding

Quantitative MR Imaging of Vascular Factors in Parkinsons DiseaseR01NS112233 · NINDS · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI HERNANDEZ-GARCIA, LUIS · 2020 to 2024
$1.8M
Silent Functional MRI Using Looping StarR01EB035618 · NIBIB · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI DOUGLAS C NOLL · 2025 to 2026
$974k
Development of Layer Specific FMRI for Clinical ScannersR21EB032514 · NIBIB · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI HERNANDEZ-GARCIA, LUIS · 2023 to 2023
$391k
Novel methods for dynamic MRI of gastrointestinal motor functionR21EB034344 · NIBIB · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI NOLL, DOUGLAS C · 2024 to 2025
$386k
NIBIB NIH HHS R01 EB035618NIBIB NIH HHS R21 EB032514NIBIB NIH HHS R21 EB034344NINDS NIH HHS R01 NS112233
6 · The paper itself

Abstract

In compressed sensing (CS) MRI, model-based methods are pivotal to achieving accurate reconstruction. One of the main challenges in model-based methods is finding an effective prior to describe the statistical distribution of the target image. Plug-and-Play (PnP) and REgularization by Denoising (RED) are two general frameworks that use denoisers as the prior. While PnP/RED methods with convolutional neural network (CNN) based denoisers outperform classical hand-crafted priors in CS MRI, their convergence theory relies on assumptions that do not hold for practical CNN models. The recently developed gradient-driven denoisers offer a framework that bridges the gap between practical performance and theoretical guarantees. However, the numerical solvers for the associated minimization problem remain slow for CS MRI reconstruction. This paper proposes a complex quasi-Newton proximal method that achieves faster convergence than existing approaches. To address the complex domain in CS MRI, we propose a modified Hessian estimation method that guarantees Hermitian positive definiteness. Furthermore, we provide a rigorous convergence analysis of the proposed method for nonconvex settings. Numerical experiments on both Cartesian and non-Cartesian sampling trajectories demonstrate the effectiveness and efficiency of our approach.

Indexed as

complex domainconvergenceCS MRIgradient-driven denoisersecond-orderspiral and radial acquisitions

Identifiers

PMID41367633
PMCPMC12685019

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.