ArticleMicrosystems & nanoengineering2025

High frame rate ultrasonic flowmeter based on PMUT array with bidirectional acoustic beams.

Yufeng Gao, Xili Wang, Lei Zhao, Aocheng Bao, Chong Yang, Ziyi Liang, Bowen Sheng, Yipeng Lu

Abstract read
In one paragraph

Article in Microsystems & nanoengineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yufeng GaoSchool of Integrated Circuits, Peking University, Beijing, China.ORCID http://orcid.org/0009-0005-0612-480X
Xili WangSchool of Integrated Circuits, Peking University, Beijing, China.
Lei ZhaoSchool of Software and Microelectronics, Peking University, Beijing, China.
Aocheng BaoSchool of Integrated Circuits, Peking University, Beijing, China.
Chong YangSchool of Software and Microelectronics, Peking University, Beijing, China.
Ziyi LiangSchool of Software and Microelectronics, Peking University, Beijing, China.
Bowen ShengSchool of Integrated Circuits, Peking University, Beijing, China.
Yipeng LuSchool of Integrated Circuits, Peking University, Beijing, China. yplu@pku.edu.cn.ORCID http://orcid.org/0000-0002-3436-3243

Funding

National Natural Science Foundation of China (National Science Foundation of China) 62471008
6 · The paper itself

Abstract

This paper demonstrated the feasibility of utilizing miniaturized piezoelectric micromachined ultrasonic transducer (PMUT) to form a symmetric V-shaped acoustic beam pattern, which enables the ability to synchronously transmit bidirectional ultrasonic signals, and offers a promising technology to address the frame rate limitations in traditional ultrasonic flowmeters based on time-of-flight (ToF). In contrast to the previous two-step flow rate monitoring scheme, where paired ultrasonic transducers are used as transmitter and receiver alternately to obtain the upstream and downstream ultrasound propagation time sequentially, we proposed one-step mid-air flow rate measurement with a remarkable frame rate through the V-shaped bidirectional beam generated by a 3.6 mm × 3.6 mm 5-channel ~250 kHz PZT PMUT phased array. By utilizing the grating lobe produced through optimized array pitch design and sequential control, this 5-channel PMUT array breaks the conventional design limitations typically associated with grating lobes, and generates the V-shaped beam with dual main lobes measured at 27° and 153°, enabling 1000 times of upstream and downstream ToF measurements in 1 s. Furthermore, installation geometry optimization was proposed to enhance the ToF resolution and adaptation to various pipe circumstances, where flow rate measurements in conventional straight pipe and optimized zigzag-shaped pipe with 150 mm sufficient ultrasound propagation length were investigated. The experiment results demonstrated the superior flow rate monitoring performance of our device and system, where large-range (0.5-35 L·min

Identifiers

PMID41366045
PMCPMC12689760

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.