ArticleScientific reports2025
Lower limb intelligent rehabilitation robot based on human-gait coupling, spatiotemporal gait sensing, and fuzzy PID control.
Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Smart exoskeleton-assisted rehabilitation after fracture surgery: closed-loop control, personalized load management, and integrated telemonitoring.Frontiers in bioengineering and biotechnology · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
For individuals with dyskinesia, postoperative walking rehabilitation is crucial, and lower limb exoskeletons provide effective training assistance. This paper proposes a method for designing a lower limb exoskeleton based on sensor feedback and human-robot gait simulation. Firstly, a mathematical model of lower limb motion and an exoskeleton robot model are designed based on hip/knee joint motion and gait mechanisms. Secondly, gait simulation is performed via human-robot coupling, with a comparative analysis of lower limb muscle dynamics during walking. Hip/knee motion data is converted into motion function curves for dynamic simulation verification. Subsequently, a brushless motor drive control system for the lower limb exoskeleton is developed using Simulink, and simulation experiments are conducted for position, speed, and torque control. Finally, patient walking experiments using membrane pressure and pose sensors analyze hip/knee and plantar pressure data, enabling output adjustment feedback and closed-loop torque control of the exoskeleton.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.