Evidence map›Paper›PMID 41362341›Full record

ArticleData in brief2025

Simultaneous electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) data during an inner speech task.

Foteini Simistira Liwicki, Rajkumar Saini, Debashis Das Chakladar, Sumit Rakesh, Vibha Gupta, Marcus Liwicki, Johan Eriksson

Abstract read
In one paragraph

Article in Data in brief, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Foteini Simistira LiwickiLuleå University of Technology, Department of Computer Science, Electrical and Space Engineering, Embedded Intelligent Systems LAB, Lulea, Sweden.
Rajkumar SainiLuleå University of Technology, Department of Computer Science, Electrical and Space Engineering, Embedded Intelligent Systems LAB, Lulea, Sweden.
Debashis Das ChakladarLuleå University of Technology, Department of Computer Science, Electrical and Space Engineering, Embedded Intelligent Systems LAB, Lulea, Sweden.
Sumit RakeshLuleå University of Technology, Department of Computer Science, Electrical and Space Engineering, Embedded Intelligent Systems LAB, Lulea, Sweden.
Vibha GuptaUniversity of Gothenburg, Gothenburg, Sweden.
Marcus LiwickiLuleå University of Technology, Department of Computer Science, Electrical and Space Engineering, Embedded Intelligent Systems LAB, Lulea, Sweden.
Johan ErikssonUmea University, Department of Psychology and Umeå center for Functional Brain Imaging, Umea, Sweden.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Inner speech, or covert speech, refers to the internal generation of language without overt articulation. Decoding inner speech has significant implications for brain-computer interfaces (BCIs), particularly for assistive communication in individuals with speech and motor impairments. To facilitate research in this area, we introduce a publicly available dataset comprising simultaneously recorded electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) data during inner speech production. Data were collected from three healthy, right-handed participants performing an inner speech task. The task involved silent repetition of visually presented words belonging to either a social or numerical category. The experiment consisted of 40 trials per word, with eight unique words and starts with a fixation period of two seconds. Stimuli were displayed for two seconds at the beginning of each session, followed by a 12-second rest period to allow hemodynamic responses to return to baseline. Participants were instructed to remain still and avoid movements to minimize artifacts. EEG was recorded using a 64-channel MR-compatible cap (BrainCap MR, EasyCap GmbH) at a 5 kHz sampling rate. Electrocardiogram (ECG) signals were simultaneously acquired using an additional electrode placed on the trapezius muscle to facilitate cardioballistic artifact correction. Gradient and cardioballistic artifacts were corrected using BrainVision Analyzer software. Functional MRI data were acquired using a 3T scanner with a 48-channel headcoil, and an echo-planar imaging (EPI) sequence optimized for whole-brain coverage. The repetition time (TR) was 2 s. High-resolution anatomical T1-weighted images were also acquired for structural reference. The dataset is publicly available in the OpenNeuro repository. The aim of this dataset is to provide a resource for studying inner speech processing, multimodal neuroimaging, EEG-fMRI fusion techniques, and BCI-driven speech prosthesis development.

Indexed as

EEGFmriInner speechMultimodal neuroimagingSynchronous data

Identifiers

PMID41362341
PMCPMC12681749

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.