ArticleMicrosystems & nanoengineering2025
Gate-tunable flexible photodetector with wavelength-selective response based on asymmetric 2D heterostructures.
Article in Microsystems & nanoengineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Broadband plasmon modulation and high-intensity nanofocusing for high-resolution nanoscale imaging using Fabry-Pérot probes.Microsystems & nanoengineering · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Flexible photodetectors with wavelength-selective response are essential for next-generation wearable and bio-integrated optoelectronics. However, conventional devices typically rely on external filters or complex structures, limiting the flexibility, integration, and broadband applications. Here, we present a gate-tunable flexible photodetector based on asymmetric van der Waals heterostructures composed of graphene, Molybdenum disulfide and single-walled carbon nanotubes. The asymmetric design induces a built-in electric field, effectively suppressing dark current and enabling dynamic modulation of spectral responsivity via gate voltage. As a result, the device achieves switchable photoresponse peaks at 450 nm and 635 nm, demonstrating a high responsivity of up to 40.3 A/W and a specific detectivity of 1.3 × 10
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.