ArticleAnalytical chemistry2025
Accurate Single-Particle Tracking and Diffusion Measurement in Freestanding Lipid Bilayers and Model Membranes.
Article in Analytical chemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Single-particle tracking (SPT) in lipid bilayers offers a powerful means to investigate the dynamic interaction of individual molecules in a variety of model membranes. However, accurate diffusion characterization in freestanding bilayers remains challenging due to membrane fragility, the potential for curvature, limited optical signal-to-background ratio, and the practical need for label concentrations that do not approximate infinite dilution. Here, we report a dual-mode fluorescence microscope configuration for bilayers formed on a microelectrode cavity array (MECAopto-inv chip) that combines widefield SPT with confocal fluorescence correlation spectroscopy (FCS). By using FCS to calibrate the SPT algorithm, we demonstrate improved measurement accuracy for diffusion constants. Importantly, we show that proper calibration resists measurement bias at high fluorescent particle concentrations. Supporting simulations confirm the robustness of this approach. When calibrated with FCS and corrected for blur, our measurements help resolve the variability in diffusion constants reported in prior literature. Furthermore, the strategy is broadly applicable to any planar bilayer system. The method provides a rigorous, quantitative benchmark for future studies involving nanopores, membrane protein assemblies, and ion-channel transport in lipid bilayers, especially when both optical and electrical information is desired.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.