Evidence map›Paper›PMID 41359228›Full record

ArticleRadiological physics and technology2026

Comparison of quantitative angiographic image quality using high kV and low kV technique, a retrospective and phantom study.

Panuwat Pattum, Woranan Kirisattayakul, Thanyalak Techasuriyawong, Suchanaree Somsuk, Waranon Munkong, Puengjai Punikhom, Rattapong Karawek

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Radiological physics and technology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Panuwat PattumInterventional Neuroradiology unit, Department of Radiology, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand.
Woranan KirisattayakulDepartment of Radiology, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand. woraki@kku.ac.th.ORCID http://orcid.org/0000-0001-5330-9421
Thanyalak TechasuriyawongBachelor of Science Program in Radiological Technology, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand.
Suchanaree SomsukBachelor of Science Program in Radiological Technology, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand.
Waranon MunkongInterventional Neuroradiology unit, Department of Radiology, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand.
Puengjai PunikhomInterventional Neuroradiology unit, Department of Radiology, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand.
Rattapong KarawekInterventional Neuroradiology unit, Department of Radiology, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand.

Funding

Khon Kaen University Research and Graduate Studies
6 · The paper itself

Abstract

Previous studies have shown that high kilovoltage (kV) angiographic imaging techniques can reduce radiation doses to patients more effectively than using low kV techniques. While radiologists often accept the resulting image quality, a detailed quantitative comparison between these techniques remains limited. This study aimed to evaluate and compare the quality of cerebral angiographic images acquired using high kV (79-90 kV) and low kV (68-82 kV) techniques on a biplane digital subtraction angiography (DSA) system. Images were analyzed from patients with cerebral aneurysms as well as a quality assurance phantom (TO DSA), focusing on 2-dimensional angiography (2D-DSA). The contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were measured at various vascular locations in posteroanterior (PA) axial and lateral views. While demographic data did not differ between groups, CNR for PA axial view and PA phantom images produced with high kV was significantly lower than that with low kV. In contrast, the high kV technique demonstrated higher SNR values in both PA and lateral views compared to the low kV technique. Radiation dose per frame confirmed a reduction in dose for the high kV protocol. Conversely, TO DSA images acquired using high kV had a lower SNR than those from low kV. The low kV technique achieved better vessel contrast, as evidenced by its higher CNR compared to the high kV technique. However, it also resulted in a lower SNR in patient images and a higher radiation dose. Protocol selection should, therefore, aim to optimize the trade-off between image quality and radiation exposure.

Indexed as

Angiography, Digital SubtractionCerebral AngiographyPhantoms, ImagingAgedFemaleHumansImage Processing, Computer-AssistedIntracranial AneurysmMaleMiddle AgedQuality ControlRadiation DosageRetrospective StudiesSignal-To-Noise RatioCerebral angiographyHigh kV techniqueIntracranial aneurysmLow kV techniqueQuantitative angiographic image quality

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked