ArticleHeart rhythm O22025
Larger spatial ventricular gradient magnitude is associated with higher rates of response to cardiac resynchronization therapy.
Article in Heart rhythm O2, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Cardiac resynchronization therapy (CRT) improves systolic heart failure (HF) outcomes, but many patients do not benefit. Improved methods for identifying patients likely to benefit from CRT are needed. The spatial ventricular gradient (SVG) is a vectorcardiographic measure of myocardial electromechanical heterogeneity that is associated with incident HF. The relationship between SVG and CRT response is unknown. Objective: This study aimed to investigate associations between SVG and CRT response. Methods: Retrospective analysis of patients presenting for clinically-indicated CRT implant in 2015-2022. Pre-CRT electrocardiograms (ECGs) were transformed into vectorcardiograms (VCGs), and SVG vector X, Y, and Z components were calculated as areas under the X, Y and Z VCG QRST complexes, respectively. SVG magnitude (SVGmag) was calculated as SVG vector length. CRT response, defined as left ventricular ejection fraction (LVEF) increase ≥10% post-CRT, was assessed using multivariable logistic regression. Results: Among 162 patients (median age 68 years, 62% male, 76% non-ischemic HF, median LVEF 26%, median QRS duration 162ms, 89% left bundle branch block), 69% had CRT response. After adjustment, larger pre-CRT SVGmag was associated with higher odds of CRT response: adjusted odds ratio (OR Conclusion: SVGmag is independently associated with CRT response and warrants prospective study.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.