ArticleCureus2025
A Case of Inadvertent Carotid Arterial Cannulation and Its Successful Closure with a Percutaneous Closure Device.
Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Percutaneous Closure of a Large-Bore Carotid Arteriotomy Using a Collagen-Based Vascular Plug.Life (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Iatrogenic carotid artery cannulation is a rare but potentially devastating complication of central venous catheterization. We present the case of an 80-year-old male with coronary artery disease who presented with syncope in the setting of complete heart block. Prior to the planned placement of a permanent pacemaker, he underwent temporary transvenous pacemaker insertion via the right internal jugular vein. Despite the use of ultrasound, his right common carotid artery was inadvertently cannulated and dilated. This was only identified after the application of a pressure transducer. As he had a prohibitive risk for open surgical repair, his right common carotid artery was then repaired less invasively with the use of a Perclose Proglide percutaneous closure device (Abbott Vascular, Inc., Santa Clara, CA, USA), leading to a successful repair without any adverse neurological outcome. A temporary pacemaker was eventually placed via the right femoral vein approach. As the patient had an ejection fraction of 35%, he eventually underwent a biventricular implantable cardioverter-defibrillator placement successfully before being discharged home without further complications. To the best of our knowledge, our case report is only the fourth case in the literature to report the off-label use of a suture-mediated closure device to repair inadvertent carotid arterial cannulation with a good outcome.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.