Evidence map›Paper›PMID 41356070›Full record

ArticleArXiv2025

Investigating the Timing Behavior of Compton Scattering in BGO for Time-of-Flight PET.

Minseok Yi, Daehee Lee, Alberto Gola, Stefano Merzi, Michele Penna, Simon R Cherry, Jae Sung Lee, Sun Il Kwon

Abstract readPreprint
In one paragraph

Article in ArXiv, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors.

Minseok Yi
Daehee Lee
Alberto Gola
Stefano Merzi
Michele Penna
Simon R Cherry
Jae Sung Lee
Sun Il Kwon

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Bismuth germanate (BGO) is gaining renewed attention as a viable material for hybrid Cherenkov/scintillation time-of-flight positron emission tomography (TOF-PET) detectors. While single-crystal studies have demonstrated excellent timing resolution by leveraging prompt Cherenkov photons, practical detector modules based on pixelated arrays introduce a high prevalence of inter-crystal scattering (InterCS) events, complicating timing accuracy. In this study, we experimentally investigated the impact of InterCS on BGO Cherenkov timing using a dual-pixel detector coupled to a segmented SiPM readout. Events were classified into full-energy deposition (FED; primary crystal 511 keV absorption), InterCS, and penetration types via energy-weighted positioning and validated using GATE simulations, which also revealed that over 25% of the experimentally identified full-energy events involved intra-crystal scatter (IntraCS). For InterCS events, the optimal timestamp selection was achieved by choosing the earlier of the two timestamps, yielding a coincidence timing resolution of 221 ps FWHM (831 ps FWTM)-markedly worse than the 184 ps (603 ps FWTM) obtained for FED events. Furthermore, prompt photon yield was found to decrease measurably due to energy splitting: InterCS events averaged 4.73 detected photons in the first 1 ns, compared to 5.76 for FED events. These results emphasize the importance of incorporating time-aware, per-pixel timestamping strategies in pixelated BGO TOF-PET systems to maintain optimal timing performance in the presence of scatter.

Identifiers

PMID41356070
PMCPMC12676387

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.