Evidence map›Paper›PMID 41353385›Full record

ArticleRadiation oncology (London, England)2025

Shortening breath-hold durations in breast radiotherapy: a novel time-control strategy for deep inspiration breath-hold VMAT.

Shilin Chen, Weigang Hu, Jiazhou Wang, Yao Xu

Abstract read
In one paragraph

Article in Radiation oncology (London, England), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Shilin ChenDepartment of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, 200032, China.
Weigang HuDepartment of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, 200032, China.
Jiazhou WangDepartment of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, 200032, China. wjiazhou@gmail.com.
Yao XuDepartment of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, 200032, China. yaoxu@mail.ustc.edu.cn.

Funding

National Natural Science Foundation of China 12375339National Natural Science Foundation of China 12475339
6 · The paper itself

Abstract

backgroundTo address the issue where single Volumetric Modulated Arc Therapy (VMAT) delivery times often exceed a patient's comfortable breath-hold capacity of approximately 20s during Deep Inspiration Breath-Hold (DIBH) radiotherapy for breast cancer, this study proposes and systematically evaluates a novel time-control optimization strategy. The goal is to reduce overall delivery time and improve temporal uniformity across individual arcs within the United Imaging Healthcare (UIH) uTPS platform.

methodsThe study included 32 left-sided breast cancer patients, with 16 having undergone breast-conserving surgery and 16 having undergone mastectomy. For each patient, 16 distinct VMAT plans were generated to compare combinations of optimization algorithms (FMO/SPO), fluence modes (FF/FFF), and various dose rates. A novel bounding factor analysis was introduced to quantify delivery bottlenecks by assessing the relative contributions of gantry rotation, MLC movement, and MU delivery to the overall treatment time.

resultsThe time-control strategy effectively reduced the mean arc delivery time and improved its uniformity across all tested combinations. The bounding factor analysis revealed that FMO plans were primarily limited by Multi-Leaf Collimator (MLC) movement, whereas SPO plans were predominantly limited by Monitor Unit (MU) delivery. Consequently, when the time-control strategy was applied to FMO plans, it shortened delivery times by restricting MLC mobility, which led to some dosimetric degradation. In contrast, for SPO plans, the strategy maintained or enhanced MLC movement while significantly reducing time, thus preserving or even improving dosimetric quality. Notably, the combination of SPO with the high-dose-rate (1400 MU/min) FFF mode reduced single-arc delivery times to approximately 10s.

conclusionsThe proposed time-control strategy is a superior solution for shortening delivery time and enhancing patient comfort without significant dosimetric compromise.

Indexed as

Breast NeoplasmsBreath HoldingRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedUnilateral Breast NeoplasmsAlgorithmsFemaleHumansRadiotherapy DosageTime FactorsBounding factorDIBHFFFFMOMLCSPOTime controlUIHVMAT

Identifiers

PMID41353385
PMCPMC12781846

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.