ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2025
Ultra-low dose post-operative CT protocol after acetabular fixation has excellent intra- and inter-observer reliability.
Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
- Erratum issued
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesWe aimed to identify a protocol with the lowest possible radiation dose for CT imaging of post-operative acetabular fractures without compromising intra- and inter-observer reliability.
designTen fresh frozen cadavers with 20 acetabuli were used. Four common fracture patterns were created, and typical fixation constructs were placed. Intentional malreduction and joint penetration were performed in some of the specimens. Each specimen was scanned with decreasing radiation dose by varying a number of protocol factors such as current and exposure time (mAs), window filters, and others. The scans were then reviewed by five fellowship trained orthopaedic traumatologists comparing against the standard, full dose CT scan of each specimen. The following parameters were assessed for each specimen: 1) articular step-off 2) articular gap 3) intra-articular implant penetration and 4) surgeon confidence. Readings were noted to be in agreement if measurement was < 2 mm.
resultsIntra-observer reliability for step-off, gap, and intra-articular implants ranged from 80 to 100% (p < 0.001) across all raters. Inter-observer evaluation of a single, pre-determined slice was 100% (average difference in rater measurements between the full dose protocol and lowest radiation protocol was 0.42 mm). The lowest radiation dose with > 80% inter-observer reliability was a soft tissue algorithm viewed in a bone window with 1.25 mm slices at 0.0625 mm pixels, 40mAs and 516 pitch (ultra-low dose CT protocol), which represents 1/10th the radiation of a full dose pelvic CT scan.
conclusionUtilizing the ultra-low dose CT protocol represents 1/10th of the radiation of a full dose CT scan, while still providing excellent intra- and inter-observer reliability.
Indexed as
Identifiers
41351644What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.