ArticleScientific reports2025
Novel T-ring-based probes for thermal ablation of tumors in different organs.
Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
- Erratum issued
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Thermal ablation has arisen as a crucial procedure for managing several solid tumors, presenting a minimally invasive choice that induces tumor mortification through localized heating. However, tumors may locate in different anatomical areas/organs, including the liver, kidney, lung, and breast. Generally, thermal ablation techniques use specific probe design that matches the tumor site and size, highlighting a noteworthy research gap in the implementation of an effective versatile probe that ablates tumors of various organs. This inspired this study to design an innovative thermal ablation T-Ring-based probes, namely the single slot with 3 T-rings (3TSS) probe, and single slot sleeved with 10 T-rings (10TSSS) probe, that enthused by the traditional single air slot probe, and the double slot sleeved probe, respectively. The proposed probes can be used at different sites in the human body, namely liver, breast, kidney, and lung. The proposed probes optimize the dissipated power consumption during the ablation process. The optimal probe's impedance is obtained by analyzing the dissipated power values with achieving the best S11 reflection coefficient values. The experimental results achieved -21.553 dB, and -24.816 dB reflection coefficients of the two new probes, 3TSS, and 10TSSS, respectively. In addition, the results validated the proposed finite element model of the proposed probe compared to a real ablation probe.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.