Evidence map›Paper›PMID 41348867›Full record

ArticlePloS one2025

Accuracy of intraoral scanners for full-arch implant scanning in the Maxilla using horizontal scanbody.

Abidiel Silva Guimarães, Thais Silva Mendonça, Paulo Sergio Borella, Gus Khalil, Junying Li, Sandra Al-Tarawneh, Lawrence Gonzaga Lopes, Gustavo Mendonça

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Abidiel Silva GuimarãesDepartment of Oral Rehabilitation and Prevention, School of Dentistry, Federal University of Goiás, Goiania, Goiás, Brazil.ORCID https://orcid.org/0000-0002-5898-5960
Thais Silva MendonçaDepartment of Oral Rehabilitation and Prevention, School of Dentistry, Federal University of Goiás, Goiania, Goiás, Brazil.
Paulo Sergio BorellaDepartment of Prosthodontics, School of Dentistry, Virginia Commonwealth University, Richmond, Virginia, United States of America.
Gus KhalilAOX Digital Designs, Orlando, Florida, United States of America.
Junying LiDepartment of Biological and Materials Sciences & Prosthodontics, School of Dentistry, University of Michigan, Ann Arbor, Michigan, United States of America.
Sandra Al-TarawnehDepartment of Prosthodontics, School of Dentistry, Virginia Commonwealth University, Richmond, Virginia, United States of America.
Lawrence Gonzaga LopesDepartment of Oral Rehabilitation and Prevention, School of Dentistry, Federal University of Goiás, Goiania, Goiás, Brazil.
Gustavo MendonçaDepartment of Prosthodontics, School of Dentistry, Virginia Commonwealth University, Richmond, Virginia, United States of America.ORCID https://orcid.org/0000-0003-2290-4046

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This laboratory study evaluated the accuracy of six intraoral scanner models (Primescan; Trios 4; Trios 5; Medit i700; i900; Itero Lumina) compared to a desktop scanner (E4) used as a control. Additionally, the influence of the scan body design, horizontal (SBH) and short cylindrical (SBC), was investigated through two different software. A master model containing six implants was used, and the scanning workflow was standardized and repeated ten times (N = 10). The data were analyzed in terms of trueness and precision using two distinct types of analysis: one performed in Blender software (Stichting Blender Foundation) and the other in Evalumap software (Claronav). The lower the number the better precision and accuracy were noted. The position deviation (3D_dev) and angular deviation (Ang_dev) were evaluated. Statistical analyses were conducted using the Kruskal-Wallis test, Bonferroni correction, and multiple comparisons. Trueness (n = 1,437) showed a significant effect on 3D_dev (p < 0.001) and Ang_dev (p < 0.001), as well as for precision (n = 6,478) in 3D_dev (p < 0.001) and Ang_dev (p < 0.001). The lowest median values for trueness in 3D_dev were observed for the i900L (35.25) and in Ang_dev for Primescan (0.35), whereas the lowest precision values for 3D_dev were found for the iTero Lumina (18.81μm) and Ang_dev in i900L (0.19 μm). Regarding the scan body type, a significant difference was observed between SBH and SBC for both trueness and precision, with SBH presenting lower angular deviation values and SBC exhibiting lower 3D position deviations. Multiple comparisons revealed significant differences for the E4 scanner across all analyses. The choice of scanner impacts both the trueness and precision of the generated models, as does the scan body type and the software.

Indexed as

Dental ImplantsImaging, Three-DimensionalMaxillaHumansSoftwareDental Implants

Identifiers

PMID41348867
PMCPMC12680154