Evidence map›Paper›PMID 41348486›Full record

ArticleClinical journal of the American Society of Nephrology : CJASN2026

Clinical Evaluation of a Disposable Test Strip for Potassium Level Measurement in Patients Treated with Maintenance Hemodialysis.

Cheol Ho Park, Yujoon Kim, Chaeeun Kim, Chaehyung Kim, Sowon Kim, Kangwon Lee, Tae-Hyun Yoo

Abstract readEvaluation Study
In one paragraph

Article in Clinical journal of the American Society of Nephrology : CJASN, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. There is No Place Like Home: Potassium Testing for Dialysis Patients.Clinical journal of the American Society of Nephrology : CJASN · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Cheol Ho ParkDepartment of Internal Medicine, Institute of Kidney Disease Research, Yonsei University College of Medicine, Seoul, Republic of Korea.ORCID 0000-0003-4636-5745
Yujoon KimDepartment of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Republic of Korea.ORCID 0009-0005-4984-177
Chaeeun KimDepartment of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Republic of Korea.ORCID 0009-0007-3500-553
Chaehyung KimDepartment of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Republic of Korea.ORCID 0009-0005-2480-1800
Sowon KimDepartment of Internal Medicine, Institute of Kidney Disease Research, Yonsei University College of Medicine, Seoul, Republic of Korea.
Kangwon LeeDepartment of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Republic of Korea.ORCID 0000-0001-5745-313
Tae-Hyun YooDepartment of Internal Medicine, Institute of Kidney Disease Research, Yonsei University College of Medicine, Seoul, Republic of Korea.ORCID 0000-0002-9183-4507

Funding

Seoul Business Agency BT230224
6 · The paper itself

Abstract

key pointsPotassium level test strip showed excellent performance with accuracy and reliability in experimental setting with standard electrolyte solutions. Potassium levels obtained with test strips yielded satisfactory agreement with those measured by central laboratory equipment.

backgroundHyperkalemia is a common electrolyte imbalance leading to an increased risk of serious cardiac dysrhythmias and mortality in patients undergoing hemodialysis. A convenient point-of-care testing (POCT) of potassium levels is considered to improve patient outcomes. However, POCT for potassium level using capillary blood with satisfactory performance is not available.

methodsWe tested the performance of disposable test strips for potassium level using various concentrations of potassium solutions with or without interfering electrolytes in an experimental setting. Subsequently, we examined the agreement between potassium levels measured by disposable test strips and those measured by central laboratory equipment using various types of blood samples, including capillary blood obtained by finger prick, in 40 patients undergoing maintenance hemodialysis. In the analysis, Passing-Bablok regression and Bland-Altman analysis were used.

resultsPotassium concentrations measured by disposable test strips showed a high degree of agreement with potassium levels achieved using inductively coupled plasma atomic emission spectroscopy. The coefficient of variations for disposable test strips were <5% across potassium concentrations ranging from 2 to 9 mM. Furthermore, potassium levels measured by disposable strips from capillary blood demonstrated a high degree of agreement with potassium levels obtained by central laboratory equipment using serum, showing the slope achieved from Passing-Bablok regression was 1.04 (95% confidence interval, 0.97 to 1.12). Additional analysis with various blood samples also showed similar results.

conclusionsPOCT for potassium level using the disposable test strip could be used for self-monitoring of blood potassium levels in clinical practice.

Indexed as

HyperkalemiaPoint-of-Care TestingPotassiumReagent StripsRenal DialysisAgedDisposable EquipmentFemaleHumansMaleMiddle AgedPredictive Value of TestsReproducibility of ResultsPotassiumReagent Stripselectrolytes

Identifiers

PMID41348486
PMCPMC12959730

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked