Evidence map›Paper›PMID 41345297›Full record

ArticleJournal of robotic surgery2025

A compact hand-held continuum manipulator for minimally invasive neurosurgery.

Rajdeep Singh, Sreejath Sivaj, Ramandeep Singh, Anuj Saini, Chander Sen, Sunil Jha, Subir Kumar Saha, Ashish Suri

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of robotic surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Rajdeep SinghDepartment of Neurosurgery,, All India Institute of Medical Sciences, New Delhi, 110029, India.
Sreejath SivajDepartment of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi, 110016, India.
Ramandeep SinghDepartment of Neurosurgery,, All India Institute of Medical Sciences, New Delhi, 110029, India.
Anuj SainiDepartment of Neurosurgery,, All India Institute of Medical Sciences, New Delhi, 110029, India.
Chander SenDepartment of Neurosurgery,, All India Institute of Medical Sciences, New Delhi, 110029, India.
Sunil JhaDepartment of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi, 110016, India.
Subir Kumar SahaDepartment of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi, 110016, India.
Ashish SuriDepartment of Neurosurgery,, All India Institute of Medical Sciences, New Delhi, 110029, India. surineuro@gmail.com.

Funding

Center of Excellence (COE) project of the Indian Council of Medical Research (ICMR), Govt. of India. 5/3/8/1/2022/MDMS(CARE)
6 · The paper itself

Abstract

Minimally invasive neurosurgical procedures are widely popular for the excision of deep-seated brain tumours and skull-base lesions. However, the limited maneuverability of the instruments due to highly confined routes and spaces is a challenge for the neurosurgeons. Even robotic arm-based interventions are difficult to implement as these procedures typically require frequent tool changes. Therefore, a combination of human dexterity and robotic intervention can be a good alternative. Accordingly, we have developed a dedicated, robotically manipulated hand-held instrument prototype that could easily maneuver in confined surgical environments. The manipulator is a continuum-type robot developed by alternate stacking of stiff and flexible discs, actuated by tendon wires attached to a high torque reduction motor. The manipulator mechanics were simulated using Cosserat-rod theory and validated through finite element analysis, physical experiments with calibrated weights. The manipulator was then integrated with a hand-held operating unit and the functionality was tested in a neuro-endo-trainer, followed by functional validation on a human cadaver head. The simplistic design and compact actuation unit of the prototype exhibited ease of fabrication, enhanced maneuverability in confined spaces and a universal appeal to the surgeons. The prototype demonstrated a maximum tip angle of 42.2° under suspended weight of 2.943 N, and successfully supported payloads up to 50 g without structural damage. Functional trials in a neuro-endo-trainer and cadaver confirmed superior maneuverability and access compared to rigid instruments, enabling smooth approach to extended or off-axis skull base regions. As such, the presented manipulator meets key design criteria for a practical, hand-held tool in minimally invasive neurosurgery and serves as a platform for future clinical translation.

Indexed as

Minimally Invasive Surgical ProceduresNeurosurgical ProceduresRobotic Surgical ProceduresCadaverEquipment DesignHumans3D printingContinuum robotsCosserat-rod theoryMinimally invasive neurosurgeryRobotic manipulators

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.