Evidence map›Paper›PMID 41345073›Full record

ArticleInternational journal for numerical methods in biomedical engineering2025

Newly Proposed Method With Noise-Reduction and Smoothing for Computational Fluid Dynamics Using Low-Resolution Medical Images.

Yoshiki Yanagita, H N Abhilash, S M Abdul Khader, K Prakashini, V R K Rao, Ganesh S Kamath, Raghuvir Pai, Masaaki Tamagawa

Abstract read
In one paragraph

Article in International journal for numerical methods in biomedical engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yoshiki YanagitaGraduate School of Life Science System and Engineering, Kyushu Institute of Technology, Fukuoka, Japan.ORCID https://orcid.org/0009-0003-8728-5685
H N AbhilashDepartment of Mechanical and Manufacturing Engineering, Manipal Academy of Higher Education, Manipal, India.ORCID https://orcid.org/0000-0001-6655-2551
S M Abdul KhaderDepartment of Mechanical and Manufacturing Engineering, Manipal Academy of Higher Education, Manipal, India.
K PrakashiniDepartment of Radiology and Diagnosis, Kasturba Hospital, Manipal Academy of Higher Education, Manipal, India.
V R K RaoDepartment of Radiology and Imageology, Great Eastern Medical School and Hospital, Srikakulam, India.
Ganesh S KamathDepartment of Radiology and Diagnosis, Kasturba Hospital, Manipal Academy of Higher Education, Manipal, India.
Raghuvir PaiDepartment of Mechanical and Manufacturing Engineering, Manipal Academy of Higher Education, Manipal, India.
Masaaki TamagawaGraduate School of Life Science System and Engineering, Kyushu Institute of Technology, Fukuoka, Japan.ORCID https://orcid.org/0000-0002-5938-346X

Funding

Japan Science and Technology Agency JPMJSP2154Japan Society for the Promotion of Science JPJSBP120197726Kyushu Institute of TechnologyManipal Academy of Higher Education
6 · The paper itself

Abstract

Recently, researchers have explored the wall shear stress (WSS) obtained from medical images and computational fluid dynamics (CFD) to provide medical support. However, low-frequency noise caused by the resolution of the medical images increases the surface roughness of the geometry, thereby reducing the calculation accuracy of WSS. To reduce the surface roughness, regular smoothing methods are applied to geometries obtained from low-resolution medical images; however volume changes are a problem. In this study, we developed a method to obtain geometries with reduced surface roughness and minimal volume changes from medical images used in checkups, which have low resolution. Our approach combines interpolation of coordinate points with selective removal of low-frequency noise. This method was applied to 12 carotid artery geometries and one cerebral artery geometry obtained from medical images during the medical checkups; the changes in surface roughness, volume, and WSS in the CFD were compared with before and after smoothing. As a result, we found that the surface roughness of the carotid artery geometries after applying the developed method was approximately 27%-32% smaller than the original geometries, with the volume change remaining minimal, approximately a few percent. The WSS in CFD was found to be approximately 4.2% lower than that of the original geometries. These results demonstrate that our approach improves CFD accuracy for carotid and cerebral arteries, making it useful for medical support based on low-resolution medical images.

Indexed as

HydrodynamicsImage Processing, Computer-AssistedModels, CardiovascularAlgorithmsCarotid ArteriesCerebral ArteriesComputer SimulationHumansStress, Mechanicalgeometry smoothing methodlow‐resolution medical imagemedical checkupsnoise filteringspline interpolation

Identifiers

PMID41345073
PMCPMC12678221

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.