Evidence map›Paper›PMID 41342820›Full record

ArticleJACC. Case reports2026

Pulse Field Ablation for Refractory Ventricular Tachycardia in a Patient With LVAD: Safety and Feasibility.

Gabriel Velez Oquendo, Shivani Mehta, Riaz Mahmood, Ugochukwu Egolum, Shalabh Chandra

Abstract readCase Reports
In one paragraph

Article in JACC. Case reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Gabriel Velez OquendoGraduate Medical Education, Internal Medicine Residency, Northeast Georgia Medical Center, Gainesville, Georgia, USA. Electronic address: Gabriel.VelezOquendo@nghs.com.
Shivani MehtaNortheast Georgia Medical Center, Gainesville, Georgia, USA.
Riaz MahmoodNortheast Georgia Medical Center, Gainesville, Georgia, USA.
Ugochukwu EgolumGeorgia Heart Institute, Advanced Heart Failure, Northeast Georgia Medical Center Gainesville, Gainesville, Georgia, USA.
Shalabh ChandraGeorgia Heart Institute, Cardiac Electrophysiology, Northeast Georgia Medical Center Gainesville, Gainesville, Georgia, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundVentricular tachycardia (VT) increases mortality in advanced heart failure. Pulsed field ablation (PFA) can offer an alternative method for VT ablation. CASE SUMMARY: A 63-year-old man with advanced heart failure and left ventricular assist device (LVAD) presented with recurrent VT and implantable cardioverter-defibrillator therapies. After 2 previous radiofrequency VT ablations, his third VT ablation combined radiofrequency with PFA. DISCUSSION: PFA represents a promising alternative to thermal ablation techniques. In our case, PFA was performed safely in a patient with an LVAD, yet it also revealed certain limitations of the current technology. Although studies in atrial fibrillation have yielded encouraging results, using PFA for VT requires further investigation to confirm both safety and efficacy, particularly regarding adequate pulse delivery to produce transmural lesions in the ventricular myocardium. TAKE-HOME MESSAGES: PFA can be used for VT ablation in patients with LVADs. Further studies are required to elucidate its effectiveness and safety.

Indexed as

advanced heart failureHeartMate 3left ventricular assist devicepulsed field ablationventricular tachycardia

Identifiers

PMID41342820
PMCPMC12905698

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.