ArticleJMIR bioinformatics and biotechnology2025
Designing a Finite Element Model to Determine the Different Fixation Positions of Tracheal Catheters in the Oral Cavity for Minimizing the Risk of Oral Mucosal Pressure Injury: Comparison Study.
Article in JMIR bioinformatics and biotechnology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Despite being an important life-saving medical device to ensure smooth breathing in critically ill patients, the tracheal tube causes damage to the oral mucosa of patients during use, which increases not only the pain but also the risk of infection. Objective: This study aimed to establish finite element models for different fixation positions of tracheal catheters in the oral cavity to identify the optimal fixation position that minimizes the risk of oral mucosal pressure injury. Methods: Computed tomography data of the head and face from healthy male subjects were selected, and a 3D finite element model was created using Mimics 21 and Geomagic Wrap 2021 software. A pressure sensor was used to measure the actual pressure exerted by the oral soft tissue on the upper and lower lips, as well as the left and right mouth corners of the tracheal catheter. The generated model was imported into Ansys Workbench 22.0 software, where all materials were assigned appropriate values, and boundary conditions were established. Vertical loads of 2.6 N and 3.43 N were applied to the upper and lower lips, while horizontal loads of 1.76 N and 1.82 N were applied to the left and right corners of the mouth, respectively, to observe the stress distribution characteristics of the skin, mucosa, and muscle tissue in four fixation areas. Results: The mean (SD) equivalent stress and shear stress of the skin and mucosal tissues were the lowest in the left mouth corner (28.42 [0.65] kPa and 6.58 [0.16] kPa, respectively) and progressively increased in the right mouth corner (30.72 [0.98] kPa and 7.05 [0.32] kPa, respectively), upper lip (35.20 [0.99] kPa and 7.70 [0.17] kPa, respectively), and lower lip (41.79 [0.48] kPa and 10.02 [0.44] kPa, respectively; P<.001 for both stresses). The equivalent stress and shear stress of the muscle tissue were the lowest in the right mouth angle (34.35 [0.52] kPa and 5.69 [0.29] kPa, respectively) and progressively increased in the left mouth corner (35.64 [1.18] kPa and 5.74 [0.30] kPa, respectively), upper lip (43.17 [0.58] kPa and 8.91 [0.55] kPa, respectively), and lower lip (43.17 [0.58] kPa and 11.96 [0.50] kPa, respectively; P<.001 for both stresses). The equivalent stress and shear stress of muscle tissues were significantly greater than those of skin and mucosal tissues in the four fixed positions, and the difference was statistically significant (P<.05). Conclusions: Fixation of the tracheal catheter at the left and right oral corners results in the lowest equivalent and shear stresses, while the lower lip exhibited the highest stresses. We recommend minimizing the contact time and area of the lower lip during tracheal catheter fixation, and to alternately replace the contact area at the left and right oral corners to prevent oral mucosal pressure injuries.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.