ReviewPathologie (Heidelberg, Germany)2026
Fourier transform mid-infrared imaging and rapid evaporative ionization mass spectrometry imaging in FFPE colorectal adenocarcinoma samples.
Review in Pathologie (Heidelberg, Germany), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundHungary ranks highest in the world regarding both the incidence and death rates of colorectal cancer. Novel analytical methods have surfaced in the past decade and are infiltrating the field of medicine. Infrared spectroscopy (IR) and mass spectrometry (MS) are frequently used for such measurements; however, multimodal techniques resulting from the combination of these have not yet gained widespread adoption.
methodsTissue microarray (TMA) of colorectal adenocarcinomas, liver metastases, and surrounding colon tissues were prepared at the Institute of Pathology, Forensic, and Insurance Medicine, Semmelweis University. From the block, 2‑ and 10-µm sections were cut for infrared and MS imaging, respectively. Infrared measurements were performed with a Perkin Elmer Spotlight microscope (Perkin Elmer Inc., Waltham, MA, USA) on samples with an area of 2200 × 2200 µm
resultsThe spectral results from the samples were noise filtered in both methods to separate the sample signal from the background. Overall, 41 cores were suitable for further data processing. For the measurements with infrared spectroscopy, the three-class classification resulted in accuracy of 0.71 and 0.71 using C‑support vector classification (SVC) and eXtreme Gradient Boosting (XGBoost) algorithms. For the analysis of the mass spectrometry data, 0.65 and 0.70 accuracy values were observed.
conclusionIdentical TMA slides have been imaged with two analytical methods. The performance of the separating algorithms was very close, which underscores the efficacy of the spectroscopy and spectrometry approach. A vector database of the spectra could be combined with the whole-slide image pixels obtained by a traditional digital scanner. A further step could be a thickness-optimized measurement, which would determine the setting for the combined measurement of the exact same sample.
Indexed as
Identifiers
41335335What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.